16
Chapter 7: Setting Bottom Platen Temperature
To set the temperature of the bottom platen, perform the following:
While the control panel is in Monitoring Mode, press and hold the Bottom Temp button.
After approximately two seconds, the panel’s Up Arrow and Down Arrow buttons will
light and the Bottom Temp button blinks, as shown in Figure 7-1. This puts the control
panel in the Set Mode. Release the Bottom Temp button. The control panel displays
the current setting for the bottom platen temperature (not the actual temperature, as
shown in Monitoring Mode); if the platen is set to off, the control panel displays three
dashes.
Figure 7-1
Setting Bottom Platen Temperature
Press either the Up Arrow or the Down Arrow button to change the setting; press and
release to increase or decrease the setting by one (1). To rapidly change the value,
press and hold the appropriate arrow button. Possible bottom platen temperature
values range from 100° to 450° Fahrenheit. To turn off the bottom platen, set the value
as three dashes,
one above 450° and one below 100°.
After you reach the temperature that you want to set for the bottom platen, press and
release the Bottom Temp button again to save the setting and return the control panel
to Monitoring Mode.
Содержание DES-30
Страница 1: ...Heat Seal Machine DES 30 Texas Automation Products Inc 300 Nichols Drive Hutchins TX 75141 ...
Страница 22: ......
Страница 23: ......