TVME201 User Manual Issue1.1.1
Page 20 of 26
IPC Control Register
VME A16 Base A 0x02C3
Bit
Symbol
Description
Access
Reset Value
7
IP C, Reset 1 = reset is initiated
Remains ‘1’, until the IP reset has been completed
and is then set to ‘0’ by the on board logic. It can
be read to verify the status of the reset.
R/W
0
6
reserved
Carry random information
R
undefined
5
reserved
R
undefined
4
reserved
R
undefined
3
reserved
R
undefined
2
IP C, Error
1 = error signal is active
R
0
1
IP C, INT1
Interrupt status
1 = indicates a pending interrupt request
R
0
0
IP C, INT0
R
0
IPD Control Register
VME A16 Base A 0x03C3
Bit
Symbol
Description
Access
Reset Value
7
IP D, Reset 1 = reset is initiated
Remains ‘1’, until the IP reset has been completed
and is then set to ‘0’ by the on board logic. It can
be read to verify the status of the reset.
R/W
0
6
reserved
Carry random information
R
undefined
5
reserved
R
undefined
4
reserved
R
undefined
3
reserved
R
undefined
2
IP D, Error
1 = error signal is active
R
0
1
IP D, INT1
Interrupt status
1 = indicates a pending interrupt request
R
0
0
IP D, INT0
R
0
Table 4-4 : IP Control Registers (IP C / IP D)