Operation
13
Tetra
Alex
®
25
Doc
No.
OM-1244364-01
2.2
tf201
322.en
Production
•
Set
the homogenising pressure
a) Adjust
the 2nd stage pressure adjusting valve to desired value or 20% of
the
homogenisation pressure.
b) Adjust
the 1st stage pressure valve to the decided value.
Check
during
production
•
Homogenising
pressure
Fine
tune by help of the 1st stage pressure adjusting valve.
•
Crankcase
oil temperature, maximum 55 ºC (131 ºF)
Risk
of
jam.
Avoid
getting
in
contact
with
the
pistons
•
Product
inlet pressure
•
If
a fault occurs, see section Trouble shooting in the Technical Manual.
Stop
•
Turn
off the pressure adjusting valves for
a) 1st
stage
b) 2nd
stage
•
Push
the stop button / Stop by external signal
Emergency
stop
•
Push
the emergency stop button only if there is a risk of damage to
personnel
or property.
Emergency
stopped
The
machine
may
contain
hot
liquid
or
cleaning
solution.
Handle
with
outmost
care
to
avoid
exposure.
•
Eliminate
the cause for the emergency stop.
•
Turn
off the pressure adjusting valves for
a) 1st
stage
b) 2nd
stage
•
Release
the emergency stop button and perform a normal start according
Start
and Production.
WARNING!
WARNING!
Содержание Tetra Alex 25
Страница 1: ...2 244364 01 fro OM Doc No OM 1244364 01 GF201862 Tetra Alex 25 Operation Manual...
Страница 10: ...Safety precautions 6 Tetra Alex 25 Doc No OM 1244364 01 2 2 tf201472 en This page intentionally left blank...
Страница 14: ...General description 10 Tetra Alex 25 Doc No OM 1244364 01 2 2 tf201372 en This page intentionally left blank...
Страница 18: ...Operation 14 Tetra Alex 25 Doc No OM 1244364 01 2 2 tf201322 en This page intentionally left blank...
Страница 20: ...Cleaning 16 Tetra Alex 25 Doc No OM 1244364 01 2 2 tf201633 en This page intentionally left blank...
Страница 23: ......
Страница 24: ...Ref text to introduction...