15
5.3 Resetting of the thermal overheating switch
Warning!
The resetting (re-connection) of the thermal switch must be conducted by a qualified
technician responsible for the maintenance of the appliance.
1.
The heater should be disconnected from the mains by pulling the plug out of the socket
outlet
2.
Check the cause of the turn-off and eliminate it
3.
Turn the switch in the direction of “-“ (MIN) till it clicks and openings coincide to each
other.
4.
Use a screw-driver or another tool ( with diameter of 2mm) to push the protection
button till you hear a click
5.
Turn the switch in the direction of “+” (MAX) in order to adjust the heating temperature.
6.
Connect the plug to the mains outlet
5.4 Fill up the water heater
1.
Open the most distant tap, used for supplying hot water in the installation (of the mixing-
faucet)
2.
Open the cold water input tap (2).
3.
When the water heater is full, there will be a continuous flow of water from the hot
water tap.
5.5 Empty the water heater
1.
Switch off the power by disconnecting the plug from the mains.
2.
Close the inflow of water from the water mains (tap 2)
3.
Open the most distant hot water tap of the mixing-faucet
4.
Open the drainage tap (8) for full emptying of the water tank!
IMPORTANT!
The manufacturer assumes no responsibility for problems resulting from incorrect assembly of
the unit to the water supply net and because of using components with unknown origin, not with
compliance to the local and European standards!
6. Protection against corrosion - magnesium anode
1.
The magnesium anode protects the water tank’s inner surface from corrosion. The anode
element is an element undergoing wear and is subject to periodic replacement.
2.
In view of the long-term and accident free use of your water heater, the manufacturer
recommends periodic inspections of the magnesium anode’s condition by a qualified
technician and replacement whenever required, and this could be performed during the
appliance’s technical preventive maintenance.
3.
For replacements, please contact the authorized service stations!