Operation and Storage Manual of Panel Heater
5
English
To activate the function – push “Mode” button
for 3 sec and select “Anti-
frost” mode
by pushing any of the buttons:
or
. Confirm with
“Mode” button
. It starts blinking and user has to push
button to
reach ‘’ON’’. Confirm with “Mode” button
.
Visualization on Display in “Anti-frost” settings
:
“Temperature correction for the sensor” function
Due to the specifics of the temperature profile in some premises there may
be difference from the temperature shown on the display and the actually
measured temperature in the various locations of the heating appliance in the
room.
See the temperature shown on the display of the appliance
Measure the temperature at a place where the temperature is “comfortable”
enough for you (usually at a height of 60 cm from the floor, in sitting positon).
If you find a difference within a range of ±4°С, you can set the necessary
correction in the convector’s menu (It is important to note that this function
can be set only after the temperature has become the same all around the
room, and depending on the room type, the minimum required time is 7
hours) by entering the temperature difference resulting between the value on
the display and the actually measured temperature.
This function is used with the purpose of providing better temperature
comfort and energy saving for the user of the electric convector in the room
which it is in. A temperature difference greater than ±4 °C from the measured
temperature in a specific location in the room indicates that the room where you
use the convector in is not well insulated or the temperature is not the same all
around the room.
Example
: a convector in a room on a stone floor – the convector displays 18°С
(the set temperature is 22°С), the actually measured temperature (feeling of
reached comfort temperature) is 22°С at a height of 60 cm from the floor - > in
this case the convector continues to overheat the room (this is a direct energy
loss, but the convector cannot reach the set temperature because it measures the
temperature at a low height close to the floor) and it will never switch off. In this
case a temperature correction of +4°С needs to be applied to the sensor, thus the
convector will display 22°С and it will start switching off, and eventually it will
maintain the set temperature of 22°С).
The normal status of the function is 0°C by default
If the customer wants to change it - by pushing “Mode”
button for 3
sec and select “Temperature correction”
mode by pushing any of the
buttons:
or
. Confirm with “Mode” button
– by pushing
or
button user can reach a temperature correction in the diapason from
‘’-4°C” up to ‘’+4°C”. Confirm with “Mode” button
.
If user wants to see the already set correction, should press “Mode” button
for 3 sec and select “Temperature correction”
mode by pushing
any of the buttons:
or
. Confirm with “Mode” button
. User can
change it by pushing button
or
to give a new value of correction in
the diapason ±4°C. Confirm with “Mode”
button.
If the factory reset function is used, the temperature correction has to be set
again. The factory setting of its value is 0°C.
Visualization on Display in “Temperature correction” settings
:
Function Adaptive start
Adaptive start is a function which predicts and initiates the optimal start of
heating in order to reach the set-point temperature at the desired time;
Test according to user instruction / documentation. The function is tested in a room
with a continuous heat demand of 50 - 60% with reference to the wattage of the
test device. The product is working at a comfort temperature 23°C ± 3°C setpoint
until stable conditions. This temperature is the reference comfort temperature “Ct”.
Activate a set-back period of 7h +2h/-0h per 24h with a set-back of 4°C ± 1°C . The
comfort period being 17 -2h/+0h hours. With the adaptive control activated - let
the heater thermostat working during 4 periods (4 x 24 hours) of comfort and low
setback cycles. After the latest low setback period finishes the comfort temperature
“Ct” should be reached within ± 30 minutes deviation to the time target - with a
maximal difference of ± 1⁰C from the reference comfort temperature “Ct”.
- Factory settings of the function is ‘’ON”
Deactivation of function Adaptive start
:
- If the customer wants to change it – by pushing the “Mode” button
for
3 sec and select “Adaptive start”
mode by pushing any of the buttons:
or
. Confirm with “Mode” button
and user can push
button
to reach ‘’OFF”. Confirm with “Mode” button
. In this case, the function
adaptive start is switched OFF.
Activation of function Adaptive start
:
To return again in condition ‘’ON’’ – by pushing the “Mode” button
for
3 sec and select “Adaptive start”
mode by pushing any of the buttons:
or
. Confirm with “Mode” button
and user can push
button
to reach ‘’ON”. Confirm with “Mode” button
. In this case the function
Adaptive start is switched ON.
Visualization on Display in “Adaptive start” settings
:
RESET to default settings
If the customer wants reset the convector to factory settings – by pushing the
“Mode” button
for 3 sec and select “RESET” mode
by pushing any of
the buttons:
or
. Confirm with “Mode” button
.
Visualization on Display in “RESET” settings
:
After using the reset function, the following functions will be re-set:
- clock time
- temperature correction value 0⁰C
- function Anti-frost mode is activated
- adaptive start is activated
- weekly program – 24/7 is reset.
Open window/door function
Room temperature control with open window detection - the product is
equipped with an integrated electronic device that reduces the heat output
when detects an open window or door. A sensor is used to detect eventual
drop in the room temperature. If the temperature falls more than 5˚C, the
convector will switch off by itself. Within 15 min the open window detection
should turn the appliance off. When the room temperature rises by at least
0.5°C and the difference from the initial set point is below 5°C, the convector
switches itself on with the settings already made. If the temperature does
not rise for more than 60 minutes, the convector enters Standby mode. The
function is allowed to be cancelled manually.
The function can be switched Off manually.
Deactivation of Open window/door function
:
If the customer wants to change it - by pushing the “Mode” button
for
3 sec and select “Open window” mode
by pushing any of the buttons:
or
. Confirm with “Mode”
button. User has to push
button
to reach ‘’OFF”. Confirm with “Mode”
button. In this case function “Open
window” is switched OFF.
Activation of Open window/door function
:
To return again in condition ‘’ON’’ – by pushing the “Mode” button
for
3 sec and select “Open window” mode
by pushing any of the buttons:
or
. Confirm with “Mode”
button. User has to push
button