background image

 

testo 315-4 · CO ambient measuring instrument 
 
 

Instruction manual 

 

Содержание 315-4

Страница 1: ...testo 315 4 CO ambient measuring instrument Instruction manual ...

Страница 2: ...2 ...

Страница 3: ...Accuracy and response time 6 3 2 3 Other instrument data 6 4 Product description 8 4 1 Overview 8 4 1 1 Control elements and connections 8 4 1 2 Display 11 4 2 Basic properties 12 5 First steps 12 6 Using the product 13 6 1 Performing settings 13 6 2 Measuring 14 6 3 Printing measurement results 15 7 Maintaining the product 16 8 Tips and assistance 17 8 1 Questions and answers 17 8 2 Calibration i...

Страница 4: ... writing standards Represen tation Explanation Note Basic or further information 1 2 Action more steps the sequence must be followed Action a step or an optional step Result of an action Menu Elements of the instrument the instrument displays or the program interface OK Control keys of the instrument or buttons of the program interface Handling prerequisite 2 2 Ensure safety Only operate the produ...

Страница 5: ...tly Use only original spare parts from Testo Temperatures given on probes sensors relate only to the measuring range of the sensors Do not expose handles and feed lines to any temperatures in excess of 70 C unless they are expressly permitted for higher temperatures 2 3 Protecting the environment Dispose of faulty rechargeable batteries spent batteries in accordance with the valid legal specificat...

Страница 6: ...urement parameter Measuring range Resolution CO 0 to 100 ppm 0 5 ppm Humidity1 5 to 95 RH 0 1 RH Temperature1 10 to 40 C 14 to 104 F 0 1 C F 3 2 2 Accuracy and response time Measurement parameter Accuracy Response time CO 3 ppm to 20 ppm 5 ppm from 20 ppm 120 s t90 Humidity 1 2 5 RH 5 to 95 RH Temperature 1 0 5 C 1 digit 3 2 3 Other instrument data Feature Values Storage transport conditions 20 to...

Страница 7: ...40 acc to EN 60529 Rechargeable battery life Typically 50 h measuring time at 20 C 68 F mains operation possible Display Segment display Supported printer 0554 0549 0554 0547 License acc to EN 50543 Warranty Instrument 24 months Rechargeable battery 12 months CO sensor 12 months Warranty terms see website www testo com warranty EU guideline 2014 30 EU ...

Страница 8: ...t description 4 1 Overview 4 1 1 Control elements and connections 1 Connection for temperature humidity module optional 2 Report printer IR interface 3 CO sensor module 4 Display 5 Keyboard 6 Reset button back 7 USB mains unit socket ...

Страница 9: ... Confirms entry next setting Long Reading display current value Opens configuration mode Reading display maximum value minimum value hold value Resets maximum value minimum value hold value Configuration mode Exits configuration mode changes are stored Short Instrument is off Switches instrument on Instrument is on Switches on display illumination switches off display illumination The display illu...

Страница 10: ... temperature Displays dew point temperature Displays CO Configuration mode Changes option increases value Long Reading display Sets zero point deletes zero point Configuration mode Increases value quickly Short Reading display Prints data Configuration mode Changes option decreases value Long Configuration mode Decreases value quickly ...

Страница 11: ...cted Alarm off alarm on Flashes the alarm threshold is exceeded not used Data transfer enabled Lights up Note Flashes Error message Differential measurement 2 Measurement functions 3 Display of CO reading humidity dew point date day and month hours and minutes measurement parameter 4 Temperature year measurement parameter 5 Settings ...

Страница 12: ...le battery only charge it at an ambient temperature of 0 to 45 C 32 to 113 F 5 First steps Switching on Connect the humidity temperature module 0636 9725 before switching the instrument on option 1 Switch instrument on press briefly All segments of the display light up for around 1 sec The warm up phase then occurs for 30 s information in display warm up During first commissioning the configuratio...

Страница 13: ... cancel the function press briefly until the display changes Adjustable functions Ensure correct settings all settings are transferred immediately There is no Cancel function Settings and display of temperature and humidity are only possible if the humidity module was connected before switching on Function Setting options comments alarm off or on on selected Enable disable acoustic signal Set CO l...

Страница 14: ...easurement view 6 2 Measuring Instrument is switched on Display of the current CO reading Switching to humidity temperature and dew point value is only possible if a humidity temperature module is connected Display humidity and temperature value press briefly Display dew point press briefly Delta measurement Instrument is in measurement view Call up Delta measurement menu press until the display c...

Страница 15: ...function press briefly The current readings are held Call up Max function press briefly The maximum readings are displayed Call up Min function press briefly The minimum readings are displayed Set Hold Max Min values to the current value press and hold down Readings flash several times and are updated 6 3 Printing measurement results Instrument is switched on Call up Print function press briefly T...

Страница 16: ...cro USB socket 2 Connect the mains plug to the mains socket The charging process will start automatically Charging is indicated by a change in the battery icon segments lights up when the battery is fully charged Cleaning the instrument Do not use any aggressive cleaning agents or solvents Mild household cleaning agents and soap suds may be used ...

Страница 17: ...our dealer or the Testo Customer Service flashes Battery capacity too low Connect the mains unit and flash E401 lights up Rechargeable battery is empty instrument will soon switch off automatically Connect the mains unit the warning can be deleted with Hold Max Min and flash Recharging the battery is impossible Contact your dealer or the Testo Customer Service Can the battery be replaced The batte...

Страница 18: ...roubleshooting did not help please contact your local dealer or the Testo Customer Service For contact data see the back of this document or website www testo com service contact 8 2 Calibration interval Testo recommends that calibration of the measuring instrument is carried out once a year by Testo Customer Service or a service centre authorized by Testo 8 3 Accessories and spare parts Descripti...

Страница 19: ......

Страница 20: ...0970 3154 en 01 V 01 00 ...

Отзывы: