TESTO 0560 3163 Скачать руководство пользователя страница 6

3

 

Product-specific information

 

 

  Only charge the battery using the original Testo mains unit supplied. 

 

  Immediately stop the charging process if this is not completed in the given 

time.  

 

Warnings 

 

Always pay attention to any information denoted by the following warnings. 
Implement the precautionary measures specified! 

 

 DANGER 

Risk of death! 

 

 

 WARNING 

Indicates possible serious injury. 

 

 

 CAUTION 

Indicates possible minor injury. 

 

 

CAUTION 

Indicates possible damage to equipment. 

 

 

 

2.2 

Disposal 

 

  Dispose of faulty rechargeable batteries and spent batteries in accordance 

with the valid legal specifications. 

 

  At the end of its useful life, deliver the product to the separate collection 

point for electric and electronic devices (observe local regulations) or return 
the product to Testo for disposal. 

 

 

 WEEE Reg. No. DE 75334352 

 

3  Product-specific information 

  Do not carry out measurements on live components. 

  Do not operate the instrument in environments above 80 %RH (condensing). 

  Observe the permissible storage and transport temperatures and the 

permissible operating temperature (e.g. protect the measuring instrument 
from direct sunlight)! 

  Always carry out a function test before searching for gas leaks. 

  If the instrument is misused or subjected to force, all warranty claims will be 

voided! 

Содержание 0560 3163

Страница 1: ...testo 316 1 EX gas leak detector 0560 3163 Instruction manual...

Страница 2: ......

Страница 3: ...tion 8 6 2 1 Establishing a Bluetooth connection to the testo Smart App 8 7 Using the product 9 7 1 Controls 9 7 1 1 Implementing settings 11 7 2 Carrying out a function test 13 7 3 Carrying out gas d...

Страница 4: ......

Страница 5: ...Do not operate the instrument if there are signs of damage on the housing mains unit or connected cables Dangers may also arise from objects to be measured or the measuring environment Always comply...

Страница 6: ...tteries in accordance with the valid legal specifications At the end of its useful life deliver the product to the separate collection point for electric and electronic devices observe local regulatio...

Страница 7: ...lammable substance in the air has a lower explosive limit LEL and an upper explosive limit UEL The air gas mixture is flammable anywhere between these two limits potentially leading to an explosion cr...

Страница 8: ...play 5 Control keys 6 Charging socket for rechargeable battery Symbol explanation Do not allow children under 6 years of age to play with batteries Do not throw batteries in the trash Do not charge ba...

Страница 9: ...on the longer this additional warming up phase should be Please note that the instrument switches itself off by default after 10 min of inactivity 1 Press and hold down 1 sec the On Off key Warm up ph...

Страница 10: ...ing is confirmed by AOFF ON or AOFF OFF 6 2 Establishing a Bluetooth connection The instrument can be connected to the testo Smart App via Bluetooth connection The gas leak detector is switched on 6 2...

Страница 11: ...The app is installed on the smartphone and connected to the instrument via Bluetooth Settings and controls are primarily carried out on the instrument and are transferred to the app To a lesser extent...

Страница 12: ...measurement data report Searching Favourite Deleting Further information Display report Multiple selection The Main menu can be accessed via the icon at top left To exit the main menu select a menu o...

Страница 13: ...ng and holding the key 1 sec Adjustable functions Ensure correct settings all settings are transferred immediately There is no Cancel function Function Setting options comments On Off long press Switc...

Страница 14: ...of the alarm sound increases as the concentration increases Unit long press Switch between PPM and LEL Measuring mode MODE 1 for gas detection MODE 2 for locating leaks Max zeroing long press Zero max...

Страница 15: ...rer Testing natural gas lines or hydrogen lines Methane main component of natural gas or hydrogen are lighter than air detection should be carried out above the pipe suspected leak Testing propane and...

Страница 16: ...falling concentration values are output At the beginning two bar segments are displayed in the middle At the same time the sensor LED flashes in a colour corresponding to the concentration value and a...

Страница 17: ...k it is advisable in the case of these larger leaks to switch to MODE 2 in order to receive feedback via audio and flashing signals If the warning threshold 100 ppm is exceeded the sensor LED and disp...

Страница 18: ...using max 0 After the measurement 1 Ventilate the sensor thoroughly after each use To do this place the instrument in fresh air for approx 2 minutes before using it again 8 Maintaining the product 8...

Страница 19: ...r inspected by an authorized service centre every year 8 3 Cleaning the sensor Tobacco smoke dirty air oils greases silicones and evaporating liquids or gases can leave deposits on the sensor surface...

Страница 20: ...se time 2 sec Leak alarm 3 colour LED on sensor head 3 colour display backlighting Acoustic App Operating temperature 5 to 50 C Operating humidity 0 to 80 RH Operating altitude 2000 m Storage temperat...

Страница 21: ...ensor error The error code is shown on the display 10 2 1 Hard Reset 1 If you encounter any problems with the firmware press and hold the ON OFF key for a long time 4 sec to perform a reset 10 3 Acces...

Страница 22: ...Testo SE Co KGaA Celsiusstr 1 79822 Titisee Neustadt Germany Phone 49 0 7653 681 0 Email info testo de www testo com 0970 3263 en 01 08 2022...