Operations
32
Testboy
®
TV 218
Operating Instructions
If the measured current exceeds the set value over a long
period of time then the meter can heat up. This can impair the
functional reliability of the internal circuitry.
To avoid discharges or inaccurate readings, do not measure
currents on high-voltage lines (over 300 V).
The meter has been set at the factory for DC mode.
Measuring AC currents
|
Set the function switch as needed.
|
Use the Select button to choose the AC current range
"AC T-rms".
|
Encircle one of the wires being measured with the current
transformer (the clamping jaws) Make sure that the clamp is
completely closed.
|
Read the measured value displayed in the "True-RMS" field.
Measuring DC currents
|
Set the function switch as needed.
|
Encircle the wire being measured with the current transformer
(the clamping jaws). Make sure that the clamp is completely
closed. Make sure the polarity indicator is correct!
|
Read the measured value.
|
It may be necessary to zero-calibrate before measuring. To
calibrate, open the close the clamps repeatedly (with no wire
inside). Then wait until the displayed value has steadied and
press the ZERO button. The value in the display should
change to about 0.00 and ZERO appears in the display.
Содержание TV 218
Страница 1: ...Testboy TV 218 Version 1 2...
Страница 57: ...Avvertenze Testboy TV 218 57 ITALIANO accumulatori...
Страница 74: ...Indicaciones 74 Testboy TV 218 pilas bater as...
Страница 83: ...Uso Testboy TV 218 83 ESPA OL en pantalla pasar a 0 00 aprox y en la pantalla se mostrar el mensaje ZERO...
Страница 92: ...Indica es 92 Testboy TV 218 baterias e acumuladores...
Страница 135: ...Testboy TV 218 135 135 136 136 137 142 142 144 145 146 147 148 148 148 149 150...
Страница 136: ...136 Testboy TV 218...
Страница 137: ...Testboy TV 218 137 CE 30...
Страница 138: ...138 Testboy TV 218 CE Testboy GmbH...
Страница 139: ...Testboy TV 218 139 Testboy Testboy Testboy...
Страница 140: ...140 Testboy TV 218 Testboy WEEE 2002 96 EC 13 08 2005 Cd Hg Pb...
Страница 142: ...142 Testboy TV 218 Testboy TV218 Testboy TV218 CAT III 300 60 30...
Страница 143: ...Testboy TV 218 143 A B C D A B C D...
Страница 144: ...144 Testboy TV 218...
Страница 145: ...Testboy TV 218 145...
Страница 146: ...146 Testboy TV 218 OFF A SR 44 LR 44 1 5 A...
Страница 147: ...Testboy TV 218 147 Select Zero Zero D H Data Hold H D...
Страница 148: ...148 Testboy TV 218 300 Select AC T rms True RMS Zero 0 00 ZERO...
Страница 150: ...150 Testboy TV 218 1 5 18 28 C 64 74 F 75 40 A 0 01 A 200 A 0 1 A 3 0 5 40 A 0 01 A 200 A 0 1 A 2 5 8 300 A DC...