Tesseract Modular Step Fader MKII Скачать руководство пользователя страница 6

CV INPUT ASSIGNMENT

The sequencer has 2 CV inputs, which can control only one parameter each. Those parameters are the

MODE

,

START

,

SIZE

,

CLOCK DIVIDER

,

KEY

(position),

TRANSPOSE

and

DUTY CYCLE

. Clicking on the

upper row will make that CV input to control a parameter of the first sequencer, and lower row of the second
one.

Please note that if the sequencer

main setup

is set to PARALLEL or SINGLE, the CV assignment for the

second sequencer (lower row) will have no effect, except for the duty cycle.

Pressing shift when in CV INPUT ASSIGNMENT mode will display the CV read value using the 2 rows of
illuminated buttons as a bar graph..

The

slide time

can also be controlled by CV (it will affect both sequencers) by clicking on the

leftmost button of the lower row (the SLIDE one) when in the CV assign mode. The concept is
more about adjusting the taste of the slide to your needs, rather than modulating the slide time,
which, on the other hand, can be done.

By default CV IN1 (and so its tall trimmer) is assigned to control the size of the sequencer 1, and CV IN2 the
clock divider (aka step repeat) of the sequencer 2.

INTERNAL CLOCK & TEMPO CONTROL

Step Fader mkII has an internal clock. Hold SHIFT and click on PLAY to start
/stop. SHIFT + RESET will do a manual reset to both sequencers.

The default tempo for the internal clock is 120 BPM. By pressing
SHIFT while clicking on

- tempo +

the internal clock will

decrease/increase in 2 BPMs. Another way to set the tempo is to
click on the TAP button at the desired speed while pressing shift. One tap for every 4 steps.

Содержание Step Fader MKII

Страница 1: ...rameters and more Each sequencer has independent settings for the play mode start point length clock divider transposition and duty cycle The 2 channels of the quantizer can be used for processing ext...

Страница 2: ...imiter 2 QIN 2 input for quantizer 2 range 0 to 10 volts RESET 2 reset input for sequencer 2 CLK 2 clock input for sequencer 2 OUTPUTS CLK 1 clock output for sequencer 1 G T 1 gate trigger 1 output VO...

Страница 3: ...s will set gate short set trigger MAIN sets the Main Setup of the module dual parallel single LOAD load preset SAVE save preset SCALE set the scale for the quantizer of both sequencers REC record mode...

Страница 4: ...e PLAY play stop for the internal clock RESET manual reset for both sequencers DIV C1 sets on off the clock division for the clock output 1 DIV C2 sets on off the clock division for the clock output 2...

Страница 5: ...does not mean that you ll get the exact same performance from the module After loading or saving a preset Step Fader mkII will return to the previous key mode KEYBOARD RECORD CLEAR The 16 illuminated...

Страница 6: ...it will affect both sequencers by clicking on the leftmost button of the lower row the SLIDE one when in the CV assign mode The concept is more about adjusting the taste of the slide to your needs rat...

Страница 7: ...malized to them a cable from the CV 1 2 output has to be plugged into either quantizer to get the V OCT output of both rows when the main setup of the sequencer is set to SINGLE In this setup all slid...

Страница 8: ...cted as follows The transposition will be the sum of all active buttons For example to get 3 semitones set ON the 1 and the 2 buttons Setting all buttons ON will have the same result as all buttons OF...

Страница 9: ...output CV 1 2 for example if it s connected to one of the quantizers input the result will be like one sequencer transposing the other also a voltage can be plugged into one of the slew inputs to per...

Страница 10: ...he module needs 11 calibration points 0V 1V 2V 9V 10V Use the CV IN 1 and CV IN 2 tall trimmers to adjust the output voltage as close as possible for every calibration point and V OCT output it will c...