TI3000 GPU-24-INV-1800
9
2
Product Overview
2.8 – AC Input Circuit Breaker
The AC input circuit breaker is located above the AC Input Connector. When the circuit breaker has been
tripped, the switch will pop out. In the event that the breaker trips:
Disconnect the ac and dc connectors. (Unplug ac line cord on military unit.)
1.
Wait for a minimum of 60 seconds.
2.
Reset breaker by pressing rocker switch.
3.
Reconnect ac and dc connections to the unit.
4.
The unit should power up automatically. If the breaker continues to trip, return the unit to Tesla™ Industries
for repair.
Figure 2.8.1 - AC Input Circuit Breaker
(outlined in blue)
2.9 – 24 Vdc Output Connector
The 24 Vdc Output Connector will provide 50 amps continuous @ 28.5 Vdc (when plugged into ac power).
When the Output Connector is not in use, cover the receptacle with the protective cover (see figure 2.9.1).
This will protect the Output Connector from dust and foreign matter.
Figure 2.9.1 - 24 Vdc Output Connector Protective Cover
Open
Closed