Storage range:
-60C
o
(-76
o
F) TO +60C
o
(+140
o
F)
(C0NTINUED ON NEXT PAGE)
3-4
CAUTION
Unit may be damaged if operated when unit’s cold or heat soaked tempera-
ture exceed the specified limit. If unit is operated when cold or heat
soaked temperature limit is exceeded, a full functional check should be
accomplished prior to continued use.
NOTE
If unit should overheat, an over-temperature sensor will shut down 120-
240 VAC functions (charger and converter) until unit cools to normal
operating temperatures.
3-11. ENVIRONMENTAL
Operating any electrical equipment in the presence of moisture cre-
ates possible safety hazards and/or potential for equipment damage.
Every effort has been made, within the scope of existing technology
to prevent foreseeable safety hazards and make the Turbo Start 2000
moisture resistant to prevent damage or failure. If the Turbo Start
3000 is exposed to moisture, preventive measures and precautions
shall be taken to:
a.
prevent accumulation of moisture on AC and DC con-
nectors/receptacles
b.
minimize moisture entering FWD inlet and AFT out-
let cooling fan vent ports
The limits and operational constraints listed below shall apply for
the following environmental (weather) conditions:
Heavy or steady rain:
OPERATION NOT RECOMMENDED
Light rain, drizzle:
NO CONVERTER OR CHARGER 120-240 VAC
fog, snow or sleet:
POWER SHALL BE APPLIED.
Unit inlet and outlet vent ports shall be covered from exposure.
Unit shall be kept horizontal.