background image

TI1000 GPU-24 UAV

29

Section 8 – Optional Accessories

8.1 – Tesla™ Shipping Case

The optional Shipping Case is the safest way to transport the TI1000 GPU-24 UAV.  This custom case weighs 

23 lbs and comes equipped with side handles and locking latches.  

8.2 – GPU Protective Covers

Protects unit from moisture, sand and other damaging elements. Custom 

fit for the TI1000 GPU-24 UAV. 

TI

7000-024

Length:  24” 

(609.60 mm)

Width: 

8.50”  (215.90 mm)

Height:  19.50”  (495.30 mm)

Weight:  23 Lbs  (10.5 kg)

NSN: 8145-01-445-3666

TI

7000-046

8.3 – Tesla™ AC Line Cords

DC power cables come in several lengths or can be custom-ordered to fit your needs. Tesla™ specializes in 

outfitting cables with a variety of connectors and junction boxes.  Contact Tesla™ Customer Service to find 

out more about our selection of cables. 

  TI

25000-211

   North American Line Cord

  TI

25000-212

   Italian Line Cord

  TI

25000-213

   Continental European Line Cord

  TI

25000-214

   Old British Line Cord

  TI

25000-215

   England / UK Line Cord

  TI

25000-216

   Swiss Line Cord

  TI

25000-201

   Australian Line Cord

  TI

25000-203

   Israel Line Cord

  TI

25000-304

   Denmark Line Cord

  TI

25000-032

   North American Commercial Line Cord

*To be used for TI3000 Commercial Unit only.

8.2 – Tesla™ AC Line Cords

These power cables come in several lengths or can be custom-ordered to fi t your needs. Tesla™ specializes 

in outfi tting cables with a variety of connectors and junction boxes.  Contact Tesla™ Customer Service to fi nd 

out more about our selection of cables. 

Regular Line Cords

  TI

25000-001

   North American Line Cord

  TI

25000-002

   Italian Line Cord

  TI

25000-003

   Continental European Line Cord

  TI

25000-004

   Old British Line Cord

  TI

25000-005

   England / UK Line Cord

  TI

25000-006

   Swiss Line Cord

  TI

25000-011

   Australian Line Cord

  TI

25000-200

   Israel Line Cord

  TI

25000-300

   Denmark Line Cord

For units with a fuse and old-style receptacle.

  Line Cords

For units with a circuit breaker and new-style receptacle.

NEMA 515P

Italian

Continental European

Old British

England/UK

Swiss

Australian

Israel

Denmark

NEMA 520P

8.1 – Tesla™ AC Line Cords

AC line cords come in several lengths or can be custom-ordered to fi t your needs. Tesla™ specializes in 

outfi tting cables with a variety of connectors and junction boxes. Contact Tesla™ customer service to fi nd out 

more about our selection of cords. 

Universal Line Cords

  TI

25000-111

 

North American Line Cord

   

105-125 Vac 60 Hz 6.50 amps max

   

NSN: 5935-01-576-4422 (CL IX)

  TI

25000-112

 

Italian Line Cord

   

10A/250V 

  TI

25000-113

 

European Line Cord

   

10A/250V-210-250 Vac 50/60 Hz 3.25 amps max

  TI

25000-114

 

Old British Line Cord

   

210-250 Vac 50/60 Hz 3.25 amps max

  TI

25000-115

 

England Line Cord

   

10A/250- 210/250 Vac 50/60 Hz 3.25 amps max

  TI

25000-120

  Israel Line Cord

   

6/10A/250V

Содержание TI1000 GPU-24 UAV

Страница 1: ...Tesla TI1000 GPU 24 UAV User Manual Built Smart Proven Tough Power Anytime Anywhere Tesla Industries Inc 101 Centerpoint Blvd New Castle DE 19720 302 324 8910 Phone 302 324 8912 Fax www teslaind com...

Страница 2: ...or injury or death by electrical shock Any attempts to open or examine the inside of the TI1000 GPU 24 UAV via a tool or device borescope probe etc can result in unit failure and or injury by electri...

Страница 3: ...in a well ventilated area May cause cancer if ingested or inhaled Causes skin irritation serious eye damage Causes damage to central nervous system blood and Contact with internal components may cause...

Страница 4: ...ot use combustible materials If possible carefully neutralize spilled electrolyte with soda ash sodium bicarbonate lime etc Wear acid resistant clothing boots gloves and face shield Do not allow disch...

Страница 5: ...mensions 7 2 6 Airflow Ports 7 2 7 Operating Positions 8 2 8 AC Input Circuit Breaker 9 2 9 24 VDC Output Connector 9 2 10 Input Voltage Selector Switch 10 2 11 Push to Test Button and LED Status Indi...

Страница 6: ...ed Questions 23 24 6 2 Basic Usage Operation Questions 24 6 3 Basic Troubleshooting 25 Section 7 Performance Data 26 7 1 Purpose 26 7 2 General 26 7 3 Data Basis 26 7 4 Specific Conditions 26 7 5 Gene...

Страница 7: ...enheit dc Direct Current EFF Efficiency ft Feet FWD Forward GPU Ground Power Unit Hr Hour Hz Hertz kg Kilograms kHz Kilohertz kW Kilowatts LED Light Emitting Diode max Maximum M megaohm min Minimum MP...

Страница 8: ...rd WARNING Indicates a condition operating procedure or practice which if not adhered to could result in serious injury or death CAUTION Indicates a condition or operating procedure which if not stric...

Страница 9: ...r user or the unit is wet while the unit is connected to a power source If the unit has come into contact with water disconnect ac power from the ac source If AC Input Circuit Breaker has tripped due...

Страница 10: ...erated during any fuel handling operation Power output is restricted to dc power only 1 5 Extreme Environments CAUTION Unit Damage Potential The unit s charger temperature switch automatically disable...

Страница 11: ...se of your new TI1000 GPU 24 UAV Ground Power Unit The TI1000 GPU 24 UAV provides DC electrical ground power for aircraft flight line maintenance and ground support operations The unit is designed to...

Страница 12: ...n occurs 24 VDC Output Connector 4 Provides 24 Vdc to 28 5 Vdc 10 A AC Input Connector 5 Connects to Single Phase 100 260 Vac line voltage 24 VDC Capacity Meter 6 Indicates the 24V battery charge stat...

Страница 13: ...e Maintenance free DC Output 10 amps continuous 28 5 Vdc when plugged into ac power Rechargeable Rate 60 minutes from full discharge 25 C Size 20 61 long x 5 2 wide x 10 56 high 523 49mm x 132 08mm x...

Страница 14: ...lugged into ac power the internal cooling system will efficiently regulate unit temperature regardless of load At room temperature 77 F the exhaust air will not exceed the ambient temperature by more...

Страница 15: ...ted in both the horizontal Figure 2 7 1 and vertical Figure 2 7 2 positions as shown Make sure that the airflow is not obstructed from air intake Figure 2 7 3 and outlet Figure 2 7 4 Figure 2 7 1 Vert...

Страница 16: ...o the unit Plug in ac line cord on military unit 4 The unit should power up automatically If the breaker continues to trip return the unit to Tesla Industries for repair Figure 2 8 1 AC Input Circuit...

Страница 17: ...witch to read 230V see figure 2 10 3 2 Rotate cover back into place Replace and tighten screw 3 Figure 2 10 2 Unscrew Protective Cover Figure 2 10 3 Select Voltage 2 10 Input Voltage Selector Switch T...

Страница 18: ...a correct reading Without ac power input or dc power output simply press the Push to Test button on the faceplate 2 and hold for approximately 2 to 3 seconds The LED bar graph should light up indicat...

Страница 19: ...t Consideration must be given to changes in performance resulting from variations in ambient temperature mode of operation state of charge with or without ac power and aircraft dc bus system inefficie...

Страница 20: ...o a cooler climate such as shade or air conditioning when possible Perform a full function test prior to use after the unit has been allowed to cool 3 6 Temperature Specifications Cold Hot Soaked Temp...

Страница 21: ...ity in excess of 0 30 inch 0 76 cm or continuously between 0 30 and 0 10 inch per hour OK OPERATION NOT RECOMMENDED Light rain drizzle or sleet Precipitation falling on a continuous basis between 0 10...

Страница 22: ...rs If no damage is evident proceed to the next step If damage is evident contact Tesla Industries Inc Figure 3 7 2 Testing DC Receptacle Check DC Voltage Reading at DC Receptacle Terminals To verify t...

Страница 23: ...negative probe to the dc negative post A Multimeter should read 0 Volts 3 Place the negative probe to the fastener screw on the dc plate Move the positive probe to the dc positive post C Multimeter s...

Страница 24: ...e and free from water Figure 3 8 1 TI1000 GPU 24 UAV 3 9 Transporting Unit The TI1000 GPU 24 UAV can be carried for short distances by hand but if the area of operation is further then 45 meters 150 f...

Страница 25: ...your line cord you can plug the unit into a wall socket to charge the batteries Until the unit is fully charged the LED status will read half or no charge Plug the TI1000 GPU 24 UAV into ac power to k...

Страница 26: ...er generator is running This feature will enable you to start multiple vehicles without reconnecting to ac power if the GPU is allowed to backcharge for approximately 30 seconds NOTE Plug the TI1000 G...

Страница 27: ...amaged if recharged by NiCad or Lithium Ion battery chargers Power cells should only be charged by either the TI1000 GPU 24 UAV s internal charger and the ac power cord furnished with the equipment or...

Страница 28: ...t cloth to remove dust dirt etc Protect Cables from Damage Do not cut crush or drag the input or output power cables when handling the unit Always inspect cables prior to use If no damage is evident p...

Страница 29: ...Seal the crate on all sides and return it to Tesla at the address listed below Please contact Tesla Customer Service at 302 324 8910 with any questions or concerns TESLA INDUSTRIES INCORPORATED 101 CE...

Страница 30: ...ormation regarding safe operation in damp environments 6 Are there any HAZMAT or disposal issues No Contact Tesla for more information 7 Are Tesla TI1000 GPU 24 UAV used in shop maintenance and testin...

Страница 31: ...rovides a way for the user to visually see the amount of available power that the unit can supply This lets the operator know if there is enough power to perform ground maintenance For more informatio...

Страница 32: ...failure A Please contact Tesla Customer Service A at 302 324 8910 4 Unit emits sparks when plugged into power source Water or moisture has seeped A in unit Internal failure B Move unit to dry warm air...

Страница 33: ...nce chart under DATA BASIS The applicable report and date of the data are also given The data provided generally are based on one of three categories Derived From Actual Controlled Testing Controlled...

Страница 34: ...50 8 13 0 8 6 20 0 68 0 53 0 127 4 45 0 49 0 12 0 10 4 21 0 69 8 54 0 129 2 44 0 47 2 11 0 12 2 22 0 71 6 55 0 131 0 43 0 45 4 10 0 14 0 23 0 73 4 56 0 132 8 42 0 43 6 9 0 15 8 24 0 75 2 57 0 134 6 41...

Страница 35: ...ation based on actual test data at Pratt Whitmey on 30 March 1992 SECONDS 1500 1350 1200 1050 900 750 600 450 150 300 0 0 5 10 15 20 25 30 29 C Temp 25 C Temp TI1000 Maximum Output Current TI1000 Outp...

Страница 36: ...r can be custom ordered to fit your needs Tesla specializes in outfitting cables with a variety of connectors and junction boxes Contact Tesla Customer Service to find out more about our selection of...

Страница 37: ...184 is the safest and easiest way to support and transport the TI1000 models out in the field and through hangars and flight lines Tesla stands behind the Transport Dolly with a team of customer serv...

Страница 38: ...ean Line Cord Burma Now Myanmar 230 50 TI25000 005 United Kingdom Line Cord Burundi 220 50 TI25000 003 Continental European Line Cord Cambodia 220 50 TI25000 003 Continental European Line Cord Cameroo...

Страница 39: ...rd Guadeloupe 220 50 TI25000 003 Continental European Line Cord Guam 110 120 60 TI25000 001 North American Line Cord Guatemala 120 60 TI25000 001 North American Line Cord Guinea 220 50 TI25000 003 Con...

Страница 40: ...n Line Cord Montseurrat 230 60 TI25000 005 United Kingdom Line Cord Morocco 220 50 TI25000 003 Continental European Line Cord Mozambique 220 50 TI25000 003 Continental European Line Cord Namibia W S A...

Страница 41: ...5000 004 Old British Line Cord Sweden 220 50 TI25000 003 Continental European Line Cord Switzerland 220 50 TI25000 006 Switzerland Line Cord Syria 220 50 TI25000 003 Continental European Line Cord Tah...

Страница 42: ...6000 19 AND MUST BE ORDERED WITH THE ORIGINAL PROCUREMENT OF UNIT S UNIT S MAY BE RETURNED TO TESLA INDUSTRIES FOR A NOMINAL COST AND MODIFIED TO ALLOW OPERATION WITH THE UNIVERSAL AC LINE CORD KIT TE...

Страница 43: ..._____________________________________________________________________________________ Purchase Order ______________________________________________________________________________ Model ______________...

Страница 44: ...Tesla Industries Inc 101 Centerpoint Blvd New Castle DE 19720 USA Tel 302 324 8910 Fax 302 324 8912 9475 Double R Blvd Suite 2 Reno NV 89521 Tel 775 622 8801 Fax 775 622 8810 www teslaind com...

Отзывы: