44
ENG
Drain pipe connection
Wrap the Piping
1. Remove the fixed part to pull out pipe of indoor machine from the case. Screw the hexagon nut in the left of the
joint to the end with your hand.
2. Connect the connecting pipe to the indoor unit:
Aim at the pipe center, tighten the Taper nut with fingers, and then tighten the Taper nut with a torque wrench,
and the direction is shown in diagram on the right. The torque used is shown in the following table.
Note
: Carefully check if there is any damage of joints before installation.
The joints shall not be reused, unless after re-flaring the pipe.
1. Use the insulation sleeve to wrap the joint part the indoor
unit and the connection pipe, and then use insulating
material to pack and seal insulation pipe, to prevent
generation of condensate water on the joint part.
2. Connect the water outlet with drain pipes, and make the
connection pipe, cables, and the drain hose straight.
3. Use plastic cable ties to wrap the connecting pipes, cables
and drain hose. Run the pipe sloping downward.
The size of pipe (mm)
Torque (Nm)
ɸ
6 /
ɸ
6. 35
15 ~ 88
ɸ
9 /
ɸ
9. 52
35 ~ 40
ɸ
12 /
ɸ
12.7
45 ~ 60
ɸ
15.88
73 ~ 78
ɸ
19.05
75 ~ 80
Tightening torque table
Indoor unit pipe
Spanner
Torgue wrench
Connecting Pipe
Drain Hose
and Cables
Plastic Strap
Taper nut Connecting
pipe
Fixing the Indoor Unit
1. Hang the indoor unit on the peg board, and move the
unit from left to right to ensure that the hook is properly
positioned in the peg board.
2. Push toward the lower left side and the upper right side of
the unit toward the peg board, until the hook is embedded
in the slot and makes a “click” sound.