14
HIGH POWER WALL CONNECTOR INSTALLATION GUIDE
Step Six - Confirm a Successful Installation
1
Set the DIP switches, located in the lower
right-hand portion of the connector, to the
test setting shown here. Use a pointed
non-conductive object such as a pen.
2
While holding the front cover near the
connector, re-connect the ribbon cable.
3
Hang the front cover over the hinge
located at the top of the connector. Do not
secure the front cover yet.
4
Turn on the power.
5
Hold the RESET button for five seconds.
This button is located on the lower right
side of the High Power Wall Connector.
You should hear the contacts close and see
the High Power Wall Connector’s lights
sequentially illuminate green.
If the RED error light illuminates or flashes, see
the Troubleshooting table on page 18 and
resolve the error before continuing.
If the RED error light is not illuminated or
flashing, continue with the next two steps.
DIP
switches
Test Mode
RESET
button is
located on
the lower
right side
HPWC_Install_Guide.book Page 14 Wednesday, April 2, 2014 3:30 PM