T-100 Series UPS User Manual 

5

 

 

 2.2 Technical Specifications 

 * O : Optional

 

 
 

 

T-102 

T-103 

T-106 

T-107 

T-110 

T-115 

Power  

2 kVA 

3 kVA 

6 kVA 

7,5 kVA 

10 kVA 

15 kVA 

Power Factor  

0.7 

>=0,9 

Automatic Battery Test 

 

Alarm Relays 

 

 

 

 

 

 

RS 232  

 

 

 

 

INPUT 

 

Input Voltage  

220 or 230 or 240 VAC 1Ph + N 

Input Voltage Tolerance 

+ 15%, -15% 

By-pass Voltage  

220 or 230 or 240 VAC 

±

10% 

Input Current 

13 A 

20 A 

35 A 

45 A 

60 A 

85 A 

Input Frequency 

50 Hz. 

±

5% 

RFI Level  

EN50091 

OUTPUT 

Nominal Output Power 

1400W 

2100 W 

4200W 

5250W 

7000W 

10500W 

Output Voltage 

220 or 230 or 240 VAC 

Output Voltage Tolerance 

±

1% 

Output Frequency 

50 Hz. 

Output Frequency 
Tolerance  

Line Synchronized 

±

 1% 

Free Running 

±

 0.2% 

Efficiency (100% Load) 

85-87 % 

Crest Factor 

3:1 

Overload capacity  

100% - 125% Load 2.5 min. 

125% - 150% Load 10 sec. 

>150% instant by-pass. 

Total Harmonic Distortion 
(THD) 

< 3% 

BATTERY 

Batteries  

14x12V 

14x12V 

20x12V 

20x12V 

20x12V 

20x12V 

Floating Charge Voltage  

189 Vdc 

189 Vdc 

270 Vdc 

270 Vdc 

270 Vdc 

270 Vdc 

End of Discharge Voltage 

140 Vdc 

140 Vdc 

200 Vdc 

200 Vdc 

200 Vdc 

200 Vdc 

Autonomy Time 
(100%Load )  

20 min. 

15 min. 

12 min. 

10 min. 

10 min. 

10 min. 

Charging Current  

1.5 A 

1.5 A 

2.5 A 

2.5 A 

2.5 A 

2.5 A 

ENVIRONMENT 

  

Operating Temperature  

0 - 40 

o

Acoustic Noise  

<42dBA 

<42dBA 

<45dBA 

<45dBA 

<45dBA 

<55dBA 

Dimension (HxWxD mm) 

540x265x560 

710x265x740 

Relative Humidity (max.)  

90 % 

Содержание T-100 Series

Страница 1: ...USER MANUAL T 100 SERIES UNINTERRUPTIBLE POWER SUPPLIES 1 Phase Input Output T 102 2 kVA T 103 3 kVA T 106 6 kVA T 107 7 5 kVA T 110 10 kVA T 115 15 kVA...

Страница 2: ......

Страница 3: ...pted 10 4 4 Operator Control Panel 10 4 4 1 Push buttons 10 4 4 2 First message Up line of the LCD 11 4 4 3 Second message line of the LCD 12 4 5 Automatic battery test system optional 12 V OPTIONAL E...

Страница 4: ......

Страница 5: ...ed service personnel The output may be energized when the unit is not connected to a mains supply Risk of electric shock hazardous live parts inside this unit are energized from the battery supply eve...

Страница 6: ...atic battery testing optional High quality maintenance free lead acid type batteries High nonlinear load capacity special for computers Accessories o Optional UPS monitoring software T MON RUPS RUPSII...

Страница 7: ...is an electronically controlled switching circuit checked by main controller board In case of inverter overload or any other faults STS transfers the critical load to the mains without any interruptio...

Страница 8: ...Voltage Tolerance 1 Output Frequency 50 Hz Output Frequency Tolerance Line Synchronized 1 Free Running 0 2 Efficiency 100 Load 85 87 Crest Factor 3 1 Overload capacity 100 125 Load 2 5 min 125 150 Loa...

Страница 9: ...Switch AC Input AC Output Output Fuse F4 External battery socket DB9 Port 2 3 kVA DB9 Port AC Output Main Switch PK1 On Off Switch UPS electrical connections 6 7 5 kVA 10 kVA Figure 2 2 Rear views DB...

Страница 10: ...Selection The UPS is designed to be installed in a protected environment The following conditions should be prohibited 1 Blocking the airflow intake and outlet It is recommended to retain 10 cm 4 mini...

Страница 11: ...d to the line voltage protected by a circuit breaker 1 Before connecting AC and DC power to the UPS make sure that the On Off Switch PK1 and Main Switch on the rear panel are in the 0 position OFF 2 C...

Страница 12: ...ll sound intermittently Now the output receptacles are supplied from the battery source 4 Connect the power again and see that LINE FAILURE alarm is off 5 Now your UPS is ready to operate Plug in the...

Страница 13: ...rotect your critical loads from loss of data or damage Battery back up time is more than 10 minutes for full load and can be extended by removing non critical loads After an utility power blackout the...

Страница 14: ...button will change the status BATT USED It shows battery operation time the time passed after the last line failure alarm MOD ONLINE MOD ECONO This parameter determines the operation type of the UPS...

Страница 15: ...out of tolerance ONLINE MODE UPS operating mode is ONLINE mode ECONO MODE optional This message shown the alternate operating mode is active OFFLINE 4 5 Automatic battery test system optional There ar...

Страница 16: ...unicate so that the computer system is warned of impending UPS shutdown Software T MON RUPS RUPSII UPSILON 2000 and SNMP devices is available for most operating systems and is supplied with a signalin...

Страница 17: ...ftware supplied with the module or it is possible to monitor the UPS through an Internet Browser It is possible to shutdown the servers or users with Client mate Software that communicates with SNMP m...

Страница 18: ...system from several different locations at the same time 5 5 UPS Port Sharer Multiple server shut down unit Using one of this units you can automatic shut down of 4 8 servers or PC where without LAN...

Страница 19: ...T 100 Series UPS User Manual 16...

Страница 20: ...T 100 Series UPS User Manual 17 Connection Diagram Of The RMP COM1 T MON...

Страница 21: ...iced only by authorized people In case of a persistent failure or problem properly turn off the unit first Then review the following check list Be prepared to answer the questions before calling the s...

Страница 22: ...not apply if the product has been subjected to physical abuse improper installation unauthorized service or modification 2 The sole responsibility of corporation under this warranty shall be limited t...

Страница 23: ...AGKK3772 02 2011...

Отзывы: