2
2. FEATURES
3-3/4 Digital LCD with Bar-graph
True RMS on ACV and ACA measurement
Water- Proof ABS housing
Auto- Ranging on Volt, Ohm , Current, Frequency, and Capacitance
measurement
Auto-power - off
Also provides MAX / MIN recording; MEM and READ; REL and data
HOLD mode
Ohms, Diode, Audible continuity, Capacitance range with input
Overload protection to 600Vrms
20A / 600V high energy fuse protection on 20A AC/DC
Flip - up stand
3 SPECIFICATIONS
3-1 General Specifications
Environment conditions
:
Installation Categories II
Pollution Degree 2
Altitude up to 2000 meters
Indoor use only
Relatively humidity 80% max.
Operation Ambient 0
〜
40
℃
Maintenance & Clearing: Repairs or servicing not covered in this
manual should only be performed by
qualified personnel.
Periodically wipe the case with a dry cloth.
Do not use abrasives or solvents on this
instruments.
Operating Principle
:
Dual slope integration
Numerical Display :
3 3/4 digit liquid crystal display (LCD)
maximum reading 3999 and Bar-graph
indication
.