background image

  If  we  press  it  again,  the  meter  main  display  will  show  T1-T2,  and  the 

secondary display will show T1, T2, in circulation. 

(7). REC/ERASE : 

    Data recording / reset datalogger 

(8). 

/

  : 

      Press this key will change the temperature scale between 

  and 

(9). T2 thermocouple input connector. 
(10). RS-232 interface.   
 

4. LCD DISPLAY DESCRIPTION 

 

(1). Negative polarity 

(10). Minimum 

(2). Low battery mark 

(11). Maximum 

(3). Time information 

(12). Memory 

(4). Timer 

(13). Relative mode 

(5). Measure mode (secondary display) 

(14). Data recording 

(6). Negative polarity (secondary display)  (15). Measure mode (Main display) 
(7). Measuring value (secondary display)  (16). K-Type 
(8). Unit “ 

  ” 

(17). Hold function 

(9). Average reading 

 

5. OPERATION INSTRUCTIONS 

(1). Plug the temperature probe into T1 or T2 input connectors. 

(2). Press 

ON

HOLD

OFF

  button once to power on the meter.    The left bottom side of 

LCD will show the date and time and then time counting status. 

(3). If “- - - - ” appears, it indicates no temperature probe or the probe is 

broken. 

(4). Input the thermocouple to measure T1 & T2 and LCD will display the value 

of  T1  &  T2  simultaneously.    If  users  want  to  obtain  the  difference  of 

T1,T2  (T1-T2),  users  can  press  the  button  of 

T1 T2
T1-T2

  .    In  addition,  the 

value of T1 & T2 will display and interchange at the right bottom side of LCD.

 

 
 

6. DATA RECORDING/ERASING RECORDS 

(1). Record one set : 

 

 

(2). Record data continuously : 

 

 

 

 Press 

  REC
ERASE

  button once, and 

the “REC” will be displayed.

 

 

Pressing 

  REC
ERASE

  button  for  3 

seconds,  “REC”  flash  1 time/sec in 

the  display.    To  set  the  interval 
time of recording, refer to page 9 .

 

Содержание TES-1307

Страница 1: ...y as specified in this manual otherwise the protection provided by the meter may be impaired Environment conditions Altitude up to 2000 meters Relatively humidity 80 max Operation Ambient 0 40 Safety symbols When servicing use only specified replacement parts Caution refer to this manual before using the meter Dangerous voltages Meter is protected throughout by double insulation or reinforced insu...

Страница 2: ...mensions 145mm L x 68mm W x 35mm H 5 7 L x 2 7 W x 1 4 H inches Weight Approx 235g with battery Accessories Instruction manual carry case battery CD Software RS 232 cable 9 pin to 25 pin gender changer 2 2 2 Electrical Specifications Basic Accuracy 23 5 Calibration Accuracy are of reading degree at 18 to 28 with relative humidity up to 80 For single thermocouple measurements Function Resolution Ra...

Страница 3: ...at had been recorded since the meter last reset c Press the button again the LCD will show M AVG The average of the first 10 records d Press the button again the LCD will show M The LCD display will be back the original status e Press and hold the button for 3 seconds the recorded maximum and minimum values will be cleared The meter will be back to the normal mode Note When MAX MIN AVG mode is sel...

Страница 4: ...ION INSTRUCTIONS 1 Plug the temperature probe into T1 or T2 input connectors 2 Press ON HOLD OFF button once to power on the meter The left bottom side of LCD will show the date and time and then time counting status 3 If appears it indicates no temperature probe or the probe is broken 4 Input the thermocouple to measure T1 T2 and LCD will display the value of T1 T2 simultaneously If users want to...

Страница 5: ...yyy MM dd hh mm Then pls press C F clock button to save the set value While in the set mode if users intend to escape from the mode and don t want to save the value users can press ON HOLD OFF to end it Each data you recorded will be saved together with date and time 7 2 Set for Recording interval time Start with the power off mode Keep pressing T1 T2 T1 T2 button then press ON HOLD OFF button tur...

Страница 6: ...connect battery from instrument and replace with a standard 9 Volt battery and replace bottom cover 9 OPTIONAL ACCESSORY K CA type thermocouple Model Range Tolerances Description TP K01 Bead probe 50 to 200 58 to 392 2 2 or 0 75 3 6 or 0 75 with Teflon tape insulation Maximum insulating temperature 260 TP K02 immersion probe 50 to 1000 58 to 1832 2 2 or 0 75 3 6 or 0 75 3 2φ 150 metal sheath 100 C...

Страница 7: ...nstruction of RS 232 interface software operation and relevant information RS 232 protocol are enclosed within the content of CD ROM please open the CD ROM for details 12 TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail tes ms9 hinet net http www tes com tw Jan 2007 5 ...

Отзывы: