Needle Scaler SN 16 PG
Operation & Maintenance Guide
FF - MM - 98 REV - 2
Sheet 4 of 4
INTENDED USE
Needle scalers are used for surface preparation work involving the cleaning or removal of paint, rust,
dirt, or weld slag from metal & non - metal surfaces. These tools also work well on irregular surfaces such as
crevices & corners. The needles are heat - treated & quickly replaceable. Needle scalers are used in marine,
offshore & petrochemical plants.
TECHNICAL DATA
SR. NO.
MODEL NO.
CAPACITY IN BPM
NEEDLES
1
N – 24
4200
1) 2mm x 180 x 53
2) 3mm x 180 x 23
2
N – 28
4750
1) 2mm x 180 x 65
2) 3mm x 180 x 28
3) 4mm x 180 x 14
3
SN- 24PG
3000
1) 2mm x 180 x 40
2) 3mm x 180 x 19
4
SN – 24ST
3000
1) 2mm x 180 x 40
2) 3mm x 180 x 19
5
SN – 20ST
4000
1) 2mm x 180 x 40
2) 3mm x 180 x 19
6
SN – 16PG
4000
1) 2mm x 180 x 29
7
SN – 29PG
2200
1) 2mm x 180 x 40
2) 3mm x 180 x 28
3) 4mm x 180 x 19
SAFETY INSTRUCTIONS:
Always wear suitable protection such as ‘eye goggles’ ear muffs’ safety shoes etc. to safeguard against possibility
of flying particles.
Never operate the tool over the rated 6.2 bar(90psi) air pressure. Do not exert excessive pressure against the
work surface. Keep hoses in good condition. Check hoses for signs of wear cracks & bulges and ensure that they
are secure. Accidental disconnection while hose is pressurized makes the hose whip and can be a safety hazard.
Please check the hose connection prior to starting Needle Scaler.
Be aware that these tools can create dust & flying debris.
Keep hands & clothing away from moving parts.
Store these tools in secure & dry environment.
Do not allow the tool to run unattended.
Do not modify this tool in any way as this will invalidate the warranty and could lead to serious injury.
Do not allow the tool to run continuously whilst not in conact with the surface being prepared.
Do not hold the exposed needles whilst the tool is in use this could cause vibration damage to the hands.
Do not use the tool in potentially explosive environments.
Do not drag this tool by air hose.