background image

FF-MM-369-REV - 02

Page 4

Operation and Maintenance Guide  4 VM Air Motor Series

Safety Instructions

      

   Warning: If not followed could      

   cause personal injuries

Caution: If not followed could result in damage 

to equipment.

    Warning  

This manual must be read and the operating  

instructions carefully followed.

   Warning

Safety and protective clothing, eyewear, head-

gear, ear protection, gloves and footwear to be 

worn during operation of  this Vane motor.

Caution

Install proper guard around the output shaft as  

needed.

Warning.

Operators under 18 not allowed to operate this 

Vane motor operators must be made familiar 

with the instructions in this manual before  

attempting to operate the Vane motor Ensure 

that job site is clear of bystanders. Do Not  

dis-assemble in explosive atmosphere.

    Caution

Use only genuine Teryair or Teryair approved 

accessories.

Warning

This Vane motor is designed for use in an ex         

 p losive environment for Zone 1 & 2 for Gas   

 and Dust.

    Warning

Operate the motor for approximately 2 hours at 

the maximum desired load. Measure the sur-

face temperature of the motor on the casting 

opposite the pipe ports. The maximum surface 

temperature listed on the   motor is for nor-

mal environmental and installation conditions. 

Fort air motors Temp. Class T6 (Gas) and T85° 

C (Dust). The maximum surface temperature 

Ex code

ll 2 G Ex h IIC T6 Gb
ll 2 D Ex h IIIC T85° C Db
Amb. Temp ( +1° C to +40° C)

Checklist for installation in    

hazardous areas

Read air motor label to check that motor has 

been designed for use in a hazardous 

 

application:
•  Hazardous zone
•  Hazardous category
•  Equipment group
•  Temperature class
•  Maximum surface temperatures

   Intended And Prohibitive Use 

     

   Intended Use

Marine and Offshore industries. Can be in 

various application subjected to availability of 

air pressure.
The design of this pneumatic vane motor is 

confirming to EN/ ISO 80079-36 and 80079-37 

explosive atmosphere suitable to use in zone 1 

& 2 area, gas group IIC and Dust group IIIC, 

temp. Class T6 (85°C).

i. EN / ISO 80079-36 : 2016 : Explosive       

atmospheres—Part 36 :Non-electrical  

equipment for explosive atmospheres— 

Basic metod and requirements

ii. EN / ISO 80079-37 : 2016 : Explosive  

atmospheres—Part 37 : Non-electrical  

equipment for explosive atmospheres—

Non-electrical type of protection construction-

al safety ‘c’, control of ignition sources ‘b’, liquid  

immersion ‘k’.
Prohibitive use
Use with non-genuine spare parts or  

accessories is prohibited

Following symbols are used through out this 

manual.

Содержание 4 VM Series

Страница 1: ...VMNXXX NEMA Model with Lube Lube Free SG Iron SS NPT BSPT Variants 4VMDXXX IEC Model with Lube Lube Free SG Iron SS NPT BSPT Variants 4 V M Read this manual carefully before installing operating or se...

Страница 2: ...cal Data Safety Instructions Installation Instructions Operating instructions Suggested Lubricants Troubleshooting Dis assembly and Re assembly Exploded View for 4VM Air Motor Bill of Materials for 4V...

Страница 3: ...35 lbs in Air Consumption 0 to 120 m3 hr 0 to 72 cfm Motor Weight 3 8 kgs 8 3 lbs Operating Pressure 1 4 to 7kg cm2 20 to 100PSI Max Allowable speed 3500 rpm ATEX limit 500 2500 2000 1000 1500 3500 3...

Страница 4: ...um surface temperature listed on the motor is for nor mal environmental and installation conditions Fort air motors Temp Class T6 Gas and T85 C Dust The maximum surface temperature Ex code ll 2 G Ex h...

Страница 5: ...If your measured temperature does ex ceed listed value consult with your Distributor Representative for a recommendation Installation Instructions An automatic air line lubricator should be in stalle...

Страница 6: ...e Check the direction of the motor airflow A single rotation motor will operate properly only in one direction Single rotation motors require a muffler to be connected to the air port Remove the plast...

Страница 7: ...or serviced Air source inadequate Inspect and repair Air source too far from motor Reconfigure setup Suggested Lubricants Brand Above 27 Deg C From 5 Deg C to 27 Deg C Below 5 Deg C Shell Toona R 72 T...

Страница 8: ...ssion Spring 17 from Rotor Shaft 4 and replace them with new ones if found damaged e From front side of motor remove Internal Circlip 20 using circlip plier from Front flange 2 then remove Oil Seal 9...

Страница 9: ...369 REV 02 Page 9 Operation and Maintenance Guide 4 VM Air Motor Series Exploded View for 4VM Air Motor 1 3 4 5 6 8 10 11 12 14 15 19 2 9 15 19 6 20 21 22 13 18 17 16 FACE FOOT 20 15 9 7 19 2 IEC NEM...

Страница 10: ...04 21 02 1 1 1 1 1 1 1 1 6 BEARING 2Z ZZ 804 50 01 2 2 2 2 1 1 1 1 7 BALL BRG 2Z ZZ 803 50 01 1 1 1 1 8 O RING 804 40 01 1 1 1 1 1 1 1 1 9 OIL SEAL 804 60 01 1 1 1 1 9 OIL SEAL 804 60 02 1 1 1 1 10 SH...

Страница 11: ...7 04 1 1 1 1 1 1 1 1 6 BEARING 2Z ZZ 804 50 01 2 2 2 2 1 1 1 1 7 BALL BRG 2Z ZZ 803 50 01 1 1 1 1 8 O RING 804 40 01 1 1 1 1 1 1 1 1 9 OIL SEAL 804 60 03 1 1 1 1 9 OIL SEAL 803 60 02 1 1 1 1 10 SHIM 8...

Страница 12: ...FF MM 369 REV 02 Page 12 Operation and Maintenance Guide 4 VM Air Motor Series Foot Mounting 4VM FACE Mounting 4VM Dimensional Data...

Страница 13: ...FF MM 369 REV 02 Page 13 Operation and Maintenance Guide 4 VM Air Motor Series NEMA Flange Mounting 4VM IEC Flange Mounting 4VM...

Страница 14: ...uide 4 VM Air Motor Series Repair KIT Ordering No Suitable for 8049701 Suitable for 4 FACE FOOT VM variant 8049702 Suitable for 4 VM IEC NEMA variant Repair Kits for 4VM Note Repair Kit includes Blade...

Страница 15: ...EN ISO 80079 36 2016 Explosive atmospheres Part 36 Non electrical equipment for explosive atmospheres Basic method and requirements EN ISO 80079 37 2016 Explosive atmospheres Part 37 Non electrical e...

Страница 16: ...after deposit with the transporter for shipment iii a Product is not properly preserved packaged stored processed or handled after receipt iv a Product is not used and maintained in accordance with T...

Страница 17: ...FF MM 369 REV 02 Page 17 Operation and Maintenance Guide 4 VM Air Motor Series This page is intentionally Left blank...

Отзывы: