When the Lift is stationary at either level:
If smoke is detected, the alarm will sound. After a period of time,
all other smoke alarms connected to the system will then start to
sound and the lift deactivates.
When the Lift is travelling between levels:
If smoke is detected, the alarm will sound. After a period of time,
all other smoke alarms connected to the system will then start to
sound.
The lift will continue to its requested level, it will remain possible
(until that level is reached) to change the direction of the lift.
Once at the desired level, the lift will deactivate.
Reactivation of Lift
The lift will automatically reactivate when the smoke alarm no
longer detects smoke and a period of two minutes has expired.
Silencing the Smoke Alarms
In either situation, it is possible that the sounder of each
individual alarm can be silenced. The alarms that has been set
off
remotely
can be silenced by pressing the both the STOP and
DOOR button on one of the lift handsets. Then the alarm that
has been triggered
by the smoke
can be silenced by pressing
the mute button on the alarm itself. Doing this will silence the
alarms for four minutes. When silenced, the lift will automatically
reactivate when a period of two minutes has expired. If the
source of smoke is not removed, the smoke alarms will begin to
sound again and the lift will be disabled.