14
2. Lowering the lift from outside the lift car.
If the lift has stopped mid level and the customer is unable to get the lift
up or down then the only time it should be lowered by the emergency
valve is if:
• There is a 2nd person around the lift area at the lower
level to ensure that nothing goes under the lift during the
lowering by the first person.
• OR the person lowering the lift has sight of the area under
the lift.
Person A:
• Ensure the lift door is fully closed.
• Turn off the mains supply to the lift.
• Locate the hydraulic power unit, normally outside the
property (see illustration below).
• Using the Torx Driver supplied, swivel the small metal
cover plate on the front face of the housing to reveal an
access hole (see illustration below).
• The red cord revealed in the access hole now needs to be
pulled continuously to lower the lift car slowly.
• After 5 seconds release the cord and check with person B
that the aperture infill panel is following the carriage. If so,
resume pulling the cord as before.
• Once the lift is at the lower level turn the mains supply
back on and secure flap.
Remove the screw using
the screwdriver provided at installation.
Swivel this metal plate to one side in
order to gain access to the lowering
cord behind the plate.
Содержание Lifestyle 3.6m