Page 16
4.5 Installation schematic
4.4 Technical Data
Pipe distance:
about 80cm
Pipe depth:
110 120cm
Type
S 5
S 7
S 8 S 10 S 12
300 300 400 500
600
For the recommended brine circulation pump see technical data on page 3.
Amount of circuits
Total length of pipe, in meter
Required area in m²
Dimensions brine circuit. DN
Length of manifold
Brine mixture in liter*
* Brine mixture (30% anti freeze content), without the amount inside the connection pipes.
3
3
4
5
6
240 240 320 400
480
25
25
25
25
25
180 180 240 300
360
105 105 140 175
210
The given required area for geothermal heat pumps is rela-
tes to average ground conditions (Soil, clay). The required
collector size and therefore the area has to be increased
for poor grounds (gravel). The circuits have to be bedded in
fine sand (0,3 0,5mm).
Contact your IDM-partner for further consultation.
Pipes from the manifold towards the cellar
An example for a TERRA 8 S-HGL heat pump with
4 circuits and a manifold connection inside the cel-
lar.
For a length of 2m, where the pipes are brought
together, they have to be insulated.
The connection pipes have to be insulated with
suitable insulation, galvanized pipes can't be
used.
A minimum distance of 1m has to be provided to
any water supply and drainage pipes as well as
to walls
Openings inside the wall have to be insulated
and made water proof.
A warning tape has to be bedded 0,5m above
the pipes.
An installation plan and photos have to be ma-
de.
The manifold connection can also be outside the
house inside a manhole.
?
?
?
?
?
?
Pipes towards the TERRA to cellar
manifold