Terra Universal Pass-Through Скачать руководство пользователя страница 7

Installation and Operating Guide  

 

Cleanroom Pass-Through Chambers 

© 

Copyright 2020 Terra Universal Inc.  All rights reserved.  • Revised Jul. 2020 • Document No. 1800-07  

 

Terra Universal, Inc.  •  TerraUniversal.com  •  800 S. Raymond Ave.  •  Fullerton, CA  92831  •  TEL: (714) 578-6000  •  FAX: (714) 578-6020 

 

 

 

 

2.3

 

Installation for CleanMount® Brackets 

 

Installation Video: 

To view a video demonstrating a similar 

installation, please visit the following link:

 

 

https://youtu.be/1tnedlfBi9w

 

 

1.

 

Prepare the wall cut-out as outlined in 

Section 2.1

 

2.

 

See 

Section 3.0

  if your pass-through chamber includes  an 

exhaust flange or filter housing for ventilation. 

 

3.

 

Standing on the “clean” side of the wall, slide the pass-through 

completely into the wall until the attached  mounting bracket is 

flush with the “clean”-side wall surface (See 

Figure 5

). 

 

4.

 

Optional support brackets are recommended if the chamber 

protrudes from the wall by 24" (See 

Figure 5

) or more. 

 

5.

 

Check alignment of the pass-through chamber doors by 

following the procedures outlined in 

Section 2.6 Door 

Alignment

 

6.

 

The “dirty”-side mounting bracket is shipped preassembled.  Pop 

off the bracket covers and slide the bracket onto the body of the 

pass-through (See 

Figure 6)

.  If necessary, detach one section of 

the mounting bracket by removing the two screws at each corner, 

creating a “C” shape.  Slide the “C”-shaped bracket onto the 

chamber and then reattach the missing section, tightening all 

corner screws once the bracket is in place. 

 

7.

 

Confirm chamber positioning with a level, and insert the provided 

lag bolts into the pre-drilled holes in the mounting bracket.  Thread 

the lag bolt into the guide that extends from the “clean”-side 

mounting bracket (See 

Figure 7

).  The size of the pass-through will 

determine the number of bolts required. Use a socket wrench to 

tighten the lag bolts into the pre-welded nuts until the mounting 

bracket is flush against the wall (See 

Figure 8

). Be careful not to 

over-tighten the “dirty”-side mounting bracket lag bolts. The bracket 

should be secured against the wall but should not bend inward 

(forming gaps).  
 

8.

 

Install the bracket covers by snapping each of them into the 

bracket clips (See 

Figure 8

 

 

 

Figure 6: 

Slide the “dirty”-side mounting bracket onto 

the body of the pass-through

Figure 5: 

Diagram of installed

 

CleanMount® Pass-through

 

Содержание Pass-Through

Страница 1: ... Document No 1800 07 Cleanroom Pass Through Chambers Copyright 2017 Terra Universal Inc All rights reserved Revised Jul 2020 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Страница 2: ...f Contents Description 3 1 0 Installation 3 2 0 2 1 Wall Cut Out 4 2 2 Installation for Standard Mounting Brackets 6 2 3 Installation for CleanMount Brackets 7 2 4 Fire Rated or Ruggedized Pass Through Installation 9 2 5 Floor Mounted Pass throughs 10 2 6 Door Alignment 11 Protruding Exhaust Flange or Filter Housing 11 3 0 Operation and Maintenance 12 4 0 4 1 Operation 12 4 2 Maintenance 12 4 3 Cl...

Страница 3: ...ersonnel All cleanroom pass throughs include a mechanical interlock system that minimizes the risk of cross contamination This device allows only one open door at a time thus minimizing the amount of dirty air that can enter the cleanroom General use pass throughs utilize a chamber mounted interlock also called a single wall design An isolated interlock or double wall design simplifies cleaning an...

Страница 4: ...ve Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 4 2 1 Wall Cut Out 1 Below chart compares the two bracket designs to help identify the mounting bracket style on your pass through CleanMount designs use lag bolts on either side of the chamber thus requiring extra clearance in the wall cut out Figure 1 from left Pass through with Standard Mounting bracket and Pass through with CleanMount Mou...

Страница 5: ...ard Add 1 2 to the width and 1 2 to the height of the outside of the chamber CleanMount Add 3 to the width and 1 to the height of the outside of the chamber 3 Add framing to the inside of the wall cut out using a rigid support material such as wood or metal 4 Finish the wall cut out with an appropriate substrate and finishing material As a general rule the wall cut out should have the same grade o...

Страница 6: ...ndard mounting or near the middle center mounting depending on the wall thickness specified in the original order 5 Insert the pass through into the wall until the fixed welded mounting bracket is flush against the wall Use a level to straighten the chamber and fasten the bracket to the wall through the pre drilled holes The number of fasteners needed depends on the size of the chamber 6 From the ...

Страница 7: ...rty side mounting bracket is shipped preassembled Pop off the bracket covers and slide the bracket onto the body of the pass through See Figure 6 If necessary detach one section of the mounting bracket by removing the two screws at each corner creating a C shape Slide the C shaped bracket onto the chamber and then reattach the missing section tightening all corner screws once the bracket is in pla...

Страница 8: ...commodate wall thicknesses between 4 and 6 Longer lag bolts are required for thicker walls not provided by Terra NOTE Although the mounting brackets are designed to provide a sufficient seal against the wall surface silicone caulking may be used to fill any seams or gaps after the installation is complete Figure 7 Thread the lag bolt into the guide attached to the clean side bracket sandwiching th...

Страница 9: ...l until the attached bracket flange contacts the wall surface 4 Ensure the bracket is flush against the wall and use a level to check the chamber positioning If necessary use shims to properly align the chamber in the wall cut out 5 Open the fire rated door and locate the predrilled holes along the interior edge Insert a fastener into the wall at each corner to temporarily tack the pass through ch...

Страница 10: ...tlined in Section 2 1 2 For pass throughs with standard mounting brackets complete the installation instructions outlined in Section 2 2 For pass throughs with CleanMount brackets flush mount complete the installation instructions outlined in Section 2 4 3 Align the floor ramps with the bottom of the pass through so that the two notches on the rear of the ramp hook onto the studs below the pass th...

Страница 11: ...rty door Raise or lower the chamber corners until the door latch engages the center of the catch Then adjust the support frame leveling feet to retain this alignment If your installation includes support brackets mount these to the chamber and the wall to achieve correct door alignment See Figure 3 in Section 2 2 above Protruding Exhaust Flange or Filter Housing 3 0 If the pass through arrived wit...

Страница 12: ...desired a mild non abrasive detergent may also be used Use only light pressure when cleaning If the outside of the acrylic is exceptionally dirty or gritty rinse the surface first by lightly swabbing a saturated cloth over the surface and allowing surfactants to drain away Avoid rubbing dirt or grit into the surface Turn the cloth often and replace with a clean cloth frequently Dry the acrylic by ...

Страница 13: ... separately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of concealed ...

Страница 14: ...irmed and Accepted Performed by Date All mounting brackets are secured tightly against the wall Support brackets if provided have been installed below the pass through No gaps larger than 1 16 exist between the pass through and the wall floor surface Pass through doors open smoothly and close completely with the latch centered in the corresponding catch The seal gasket on the inside of each door i...

Отзывы: