7. Operating
7.1 Initial configuration
All modules leave the factory with this control Ethernet interface IP address:
192.168.1.10
. In order to avoid conflicts with
other IP addresses, it is necessary to perform an initial configuration in local mode. Subsequently, it will be possible to access
the modules via the local area network (LAN), either to re-programme it or to check is operating status.
The modules leave the factory with the following Control Ethernet interface TCP/IP configuration:
IP address of the module
:
192.168.1.10
Subnet mask
:
255.255.255.0
Default Gateway
:
192.168.1.1
To access each module, use a PC or MAC personal computer equipped with an Ethernet
card and RJ-45 cable (CAT-5E or CAT-6). The IP address of the PC/MAC must be configured
within the following range: 192.168.1.2 - 192.168.1.254 (do not use 192.168.1.10, since this
is the IP address of the module to be configured). To start the configuration of the module,
open your web browser and type in the following direction: http://192.168.1.10. The login
prompt will appear on the screen (see Figure 6).
Figure 6. Login prompt
Access to the site is protected by user name and password. The default user name and password is
admin
. Enter the
user name and password and click on "Login
"
button.
Note
: the default password -
admin
- can (and must) be changed as explained on section
7.8.5
.
During initial configuration you need to change the default control and streaming Ethernet interfaces TCP/IP configuration
as explained on section
7.5
.
Control interface IP address reset to default procedure: press the "RESET" [7] button (Figure 1) for more than 3 seconds and
release it. After this operation the control interface IP address will be set to
192.168.1.10
, user name and password set to
admin
.
7.2 General configuration
Initial program screen
The first screen that appears when the module accessed contains the "Main" window, which gives general information
on the device.
Figure 7. General information screen
In the top of each configuration screen you will see a main menu tabs [1].
Using it, you can switch between the different configuration menus. The tab highlighted in yellow shows which menu is
active at a given moment. The "System menu" tab contains several submenu.
Also common elements for all screens is module title [2] and login information strings [3]. The module title can be changed
after pressing the "Change" button in the "Device information" table. Pressing on the "Logout" string you can logout from
module control.
[1]
[2]
[3]