background image

Water supply 3/8” O.D. unplated copper 
tube. Waste 1-1/4” IPS. Contractor to 
supply waste trap and service stop valve 
in accordance with local code.

Connecting lines to be made of unplated 
copper and should be thoroughly flushed 
to remove all foreign matter before being 
connected to fountain. This fountain is 
manufactured in such a manner that it 
does not in any way cause taste, odor, 
color, or sediment problems.

Connect fountain to supply line with a shut-
off valve and install a 3/8” unplated copper 
water line between the valve and the 
cooler. Remove any burrs from from outside 
of water line. Push the tubes straight into 
the fittings until they reach a positive stop, 
approximately 3/4” (see figures 2 and 3). 

DO NOT SOLDER TUBES INSERTED INTO 
THE STRAINER AS DAMAGE TO THE 
O-RINGS MAY RESULT.

These products are designed to operate on 
20 psig to 105 psig supply line pressure. If 
inlet pressure is above 105 psig, a pressure 
regulator must be installed in the supply 
line. Any damage caused by reason of 
connecting this product to supply line 
pressures lower than 20 psig or higher than 
105 psis is not covered by warranty.

This fountain is to be mounted on a 
smooth, flat, finished surface with 
adequate support structure. 

NOTE: Mounting structure must be 
capable of supporting 300 lb. load on 
fountain.

Refer to rough-in for plumbing.

Install shut-off valve on water supply.  
(valve not furnished)

Locate and install fountain using 3/8” 
minimum anchor screws or bolts.  
(screws or bolts not furnished)

CAUTION: This fountain is rated for inlet 
water pressure of 20-105 PSI. A pressure 
reducing regulator should be used if the 
inlet water supply exceeds 105 PSI.

Connect water supply and fountain drain. 
Water connection & drain must comply 
with local codes.

Turn on water supply and check all 
connections for leaks.

1

1

2

2

3

3

4

4

5

6

GENERAL INSTALL TIPS

START UP

11 1/2”

292 mm

5 3/8”

137 mm

18”

457 mm

15 1/12”

394 mm

19 1/2”

495 mm

15 1/2”

394 mm

15 1/2”

394 mm

35 1/4”

895 mm

FIGURE 1

 

2

D F - 3 8   —   O w n e r ’s   M a n u a l

1 1/4”

32 mm

WASTE LINE

3/8”

10 mm

O.D WATER 

INLET

IMPORTANT! INSTALLER PLEASE NOTE

 Wall mounting structure must be capable of supporting 300 lb. load on fountain.

Содержание DF-38

Страница 1: ...E PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER ...

Страница 2: ... damage caused by reason of connecting this product to supply line pressures lower than 20 psig or higher than 105 psis is not covered by warranty This fountain is to be mounted on a smooth flat finished surface with adequate support structure NOTE Mounting structure must be capable of supporting 300 lb load on fountain Refer to rough in for plumbing Install shut off valve on water supply valve no...

Страница 3: ...remove tubing from the fitting relieve water pressure push in on the gray collar while pulling on the tubing see figure 3 1 4 O D TUBE WATER INLET TO COOLER 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 25mm APPROXIMATELY STREAM HEIGHT Stream height is factory set at 45 50 PSI If supply pressure varies greatly fro...

Страница 4: ...Assy 6 70021C Set Screw 8 32 x 25 7 NA Screen 8 45660C Bubbler Assy 9 100322740560 Bubbler Gasket 10 60985551640 Drain Plug Assy 11 170705042830 Basin Receptor 12 15013C Bubbler Tube Assy 13 100147140560 Drain Gasket 14 55913C Drain Fitting 15 75588C Slip Joint Nut 1 1 4 16 66346C Drain Tube 17 55996C Strainer In Line 1 2 3 4 5 7 6 8 9 9 10 11 13 14 12 15 17 16 ...

Отзывы: