the picture)
Use the machine's components (screws and expansion pipe) fix on the wall as following figure, then mounted the
machine.
1
、
The distance between the product and the ceiling(and the
side) should be
≥
30cm.
2
、
Product installation size see Figure.
3
、
Note: when the product is installed, The hook (screw) is
aligned with the hole "A" on the product. After hanging, must be
moved to the "B", in order to firmly fix.
When to remove the product, must be moved from "B" to "A"
then take out.
TECHNICAL FEATURES
Model
Rated Power
Rated Voltage
Rated Frequency
Class II
TERMOZETA TZR06N
2000W
220-240V~
50-60Hz
USAGE
1. Please make sure the capacity should be 220-240V~, 50-60Hz.
2. Put the plug in the wall socket.
3. Switch the appliance on by selecting the desired setting.
“0” is “OFF”. “I”: is “ON”.
4. Use the machine according to the buttons on the infrared remote control. (The remote control keys are shown
below).
1
、
Turn on the power switch, LED display Environment
temperature, the appliance is standby.
2
、
At the right side of the appliance base have a switch, Press
“START/STOP”, High heat, press again, the appliance will
shutdown.
3
、
All function need to be operated by remote control.
4
、
Fan keep working for 30 seconds when shutdown the
appliance(after heating)
Note: The indicator lights when corresponding function is working