2. Self-cleaning bottom of the burner to automatically remove the ash residues from the burner
pot
•
Ignition, start-up and turning-off are fully automatized. Combustion control is optimized using
algorithms such as ‘modulation’ which automatically decreases pellet dose as the difference between
desired and reached temperature is decreasing.
•
Boiler is easily connected to a room wi-fi thermostate.
•
As required by the European norm EN 303-5 boiler chamber is made by welding 5mm thick steel
plates (all surfaces in touch with fire). Other parts are made of 4mm steel.
•
Safety features:
Pellets are fed to boiler via internal transporter screw inside the storage tank. From there pellets
are fed over to heating chamber where they fall free to the designated combustion area (the ’actual’
embedded burner of the boiler). Storage and combustion area are physically divided. There is a
safety thermostat to prevent back-fire. There is also an anti-explosion safety device on the right
side of the heating chamber.