Cooking is possible in every working mode of the stove-boiler.
Before any operation it is necessary to clean the boiler and check the pressure of the entire system.
9
Overheat protection using the thermostatic valve (closed system)
TEMY PLUS P has an embedded heat exchanger inside the heating chamber (position 12) which has to
be connected to the thermostatic overheat protection valve (such as Danfoss BVTS, Caleffi or Watts). If
the water temperature rises, the valve will open and let cold water through the heat exchanger system;
thus quickly and efficiently lowering the temperature.
The valve will operate safely regardless of the ambient temperature, and the self-acting technology means
that the valve does not recquire electricity or other forms of energy in order to work.
Description of the parts: 1. Cold water entrance toward the heat exchanger 2. Sensor of the thermostatic
valve 3. Exit for hot water from the heat exchanger
How to connect the valve: