![TERMET ThermElite TE125HLP Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/termet/thermelite-te125hlp/thermelite-te125hlp_installation-and-operating-instructions-manual_1089165004.webp)
ISU-217:2004 cz
ęść
angielska
3
battery sparker. Before operating this unit, two D-Cell batteries are to be installed in
the battery compartment.
To accomplish this, first remove the front shield by holding it with both hands at the
bottom edges and pulling it gently toward you. When both prongs come out of the
holes in the front shield, lift the shield about 4 inches until both screws come out of
the heater’s back shield. Take care when doing this so as not to damage the
battery compartment. Now open the battery compartment by depressing the push-
button as illustrated in Fig.1. Install two D-Cell batteries in the battery
compartment, aligned as indicated. Close the lid of the battery compartment.
Replacing the front shield can only be done when the temperature selection knob
and gas control knob are removed.
Fig. 1
Opening the battery compartment
3. Open the natural gas line valve running to the heater. For liquid propane models,
open the valve at the gas cylinder or tank.
4. Rotate the gas control knob from position “0” to one out of four gas flow positions
Fig. 2
Control panel
*Only on heater TE80X and TE125X
Temperature selection knob
Gas control knob
Battery indicator*
Note
: If the battery status indicator is flashing, promptly replace old batteries.