The gas conversion for models TE125P and TE80P consists of following steps:
1. Replacement of gas cone and gas cone seat in gas-water unit (see table
below),
2. Replacement of nozzles in the main burner,
3. Replacement of a nozzle in the ignition burner
4. Leak tests
5. Adjustment
6. Record in a Warranty Book
Models: TE80X, TE80H, TE125X, TE125H
Part
Drawing
number
Number
of pieces
per unit
Remarks Image
Gas cone I
TE125 NG
TE 125 LP
TE80 NG
TE80 LP
053.03.00.01
054.03.00.01
383.03.00.01
384.03.00.01
1
1
1
1
Inner diameter
Ø 8,30
Ø 6,59
Ø 8,43
Ø 6,75
Gas cone II
TE125 NG
TE125 LP
TE80 NG
TE80 LP
053.03.00.03
054.03.00.03
383.03.00.03
384.03.00.03
1
1
1
1
Inner diameter
Ø 8,49
Ø 6,72
Ø 8,50
Ø 6,80
Gas cone seat
TE125 NG
TE125 LP
TE80 NG
TE80 LP
053.03.00.02
054.03.00.02
372.03.00.02
383.03.00.02
1
1
1
1
Inner diameter
Ø 9
Ø 7
Ø 9
Ø 7
Main burner nozzle
TE125 NG
TE125 LP
TE80 NG
TE80 LP
053.01.00.01
374.01.00.01
373.01.00.01
374.01.00.01
18
18
12
12
Designation
126
72
126
72
Ignition burner
nozzle
TE125 NG
TE125 LP
TE80 NG
TE80 LP
383.12.00.01
384.12.00.01
383.12.00.01
384.12.00.01
1
1
1
1
Designation
13
74
13
74