12.0 Safety distance and placement of the stove
The below mentioned distances are
minimum distances
relevant for this stove. These minimum
distances must be respected according to the approval.
At these minimum distances the wall can still become warm,(Up to 80°C). To avoid discolorations,
smelly odor from warm paint, to maximize the heat output,
and making the cleaning easier, we recommend that you keep an distance of 80 – 100 mm.
If the wall´s around the stove is of noncombustible materials we also recommend a distance of
80 – 100mm.
* Please note
, that the requirements for the flue pipe and chimney systems will be different
from the stoves.
12.1. Safety distances to flammable materials using UNINSULATED fluepipes*:
Distance to inflammable wall behind stove:
100mm
Photo 1:
Distance to inflammable side wall:
350mm
Photo 1:
Distance by corner placement of 45°:
50mm
Photo 2:
Møbleringsafstand:
1200mm
Photo
1
Photo
2
12.2. Safety distances to flammable materials using INSULATED fluepipes*:
Distance to inflammable wall behind stove:
50mm
Photo 1:
Distance to inflammable side wall:
350mm
Photo 1:
Distance by corner placement of 45°:
50mm
Photo 2:
Møbleringsafstand: 1200mm
Photo
1
Photo
2