Unit does not cool correctly.
You can achieve the most effective and
economical cooling comfort if room has not
yet been heated up. Air Conditioner operates
more effectively if room temperature has
not raised and has been kept steady. To
drastically cool the air in a very hot room
requires much more time and energy.
TROUBLESHOOTING
ERROR/
PROBLEM
SUGGESTED REMEDY
CAUSE
Observe all data in these operating
instructions concerning function range.
New measurement of start temperature.
Please switch the Unit off and start it
again after approx. 30 minutes. If the error
occurs continuously, the Unit requires the
intervention of Authorized Technical Service.
Temporary error on measuring output
temperature.
Please switch the Unit off and start it
again after approx. 30 minutes. If the error
occurs continuously, the Unit requires the
intervention of Authorized Technical Service.
This error message in the Cooling function
refers to too high ambient temperatures, and in
the Heating function to too low temperatures.
Please observe the instructions relating to
ideal operation of the Unit.
Error Code E3 may also be referred to a
temporary error measurement between the
start and output temperature. Please switch
the Unit off and start it again after approx. 30
minutes. If the error occurs continuously, the
Unit requires the intervention of Authorized
Technical Service.
If the water tank is full, the Error Code E4
appears on display and Unit stops operation.
Remove the rubber cap at the bottom of
Unit and let water come out into an external
container. As soon as water has been
completley removed, it is possible to start
Unit again.
E1
Room temperature
outside the function
range=
Room temperature
inside the function
range=
E2
Refrigerant pipes’
temperature is too
high or too low.
E3
Incorrect signal.
E4
Water tank full.
DF
Defrosting operation.
This procedure is completely normal and
protects the system from icing and failure.
The Unit automatically starts again after
approx. 15 minutes (depending on the
function setting).
This procedure repeats itself regularly.