Page 46/62
Rev. A
2017-12-04
SCANTER 1002 Radar System
User’s Manual
1255194-HO
Name
Min
Max
Severity
Description
Control Error#Motor Controller
Error
Control Link Down#ClutterMap
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link Down#CoreTracker
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link Down#ET2
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link Down#Motor Con-
troller
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link Down#Network
Configurator
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link
Down#NTPWatch#ET2
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link
Down#NTPWatch#HK
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link Down#PlotCombiner
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link Down#PlotPublisher
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link
Down#PlotServer#Air
Error
Indicates that the communication between the main software
node and the software node specified is not established
Control Link
Down#TrackPublisher
Error
Indicates that the communication between the main software
node and the software node specified is not established
Core Tracker Input Link
Error
Could not connect to data input source.
CPU Load Error#HousekeepingPC
106
100000
Error
Indicates that the CPU is heavily overloaded
CPU Load Error#TrackerPC
106
100000
Error
Indicates that the CPU is heavily overloaded
CPU Load Warn-
ing#HousekeepingPC
101
105
Warning
Indicates that the CPU is slightly overloaded
CPU Load Warning#TrackerPC
101
105
Warning
Indicates that the CPU is slightly overloaded
Custom antenna pattern Error
Error
Drive I2T Protection Warn-
ing#Motor Controller
Warning
Drive Over Temperature Er-
ror#Motor Controller
Error
Содержание SCANTER 1002
Страница 2: ......
Страница 4: ...Page 4 62 Rev A 2017 12 04 SCANTER 1002 Radar System User s Manual 1255194 HO Intentionally left blank...
Страница 10: ...Page 10 62 Rev A 2017 12 04 SCANTER 1002 Radar System User s Manual 1255194 HO Intentionally left blank...
Страница 26: ...Page 26 62 Rev A 2017 12 04 SCANTER 1002 Radar System User s Manual 1255194 HO Intentionally left blank...
Страница 42: ...Page 42 62 Rev A 2017 12 04 SCANTER 1002 Radar System User s Manual 1255194 HO Intentionally left blank...
Страница 50: ...Page 50 62 Rev A 2017 12 04 SCANTER 1002 Radar System User s Manual 1255194 HO Intentionally left blank...
Страница 58: ...Page 58 62 Rev A 2017 12 04 SCANTER 1002 Radar System User s Manual 1255194 HO Intentionally left blank...
Страница 61: ......