71M6534H Demo Board User’s Manual
Page: 14 of 86
© 2005-2007 TERIDIAN Semiconductor Corporation
V2-0
1.7.3 CHECKING OPERATION
A few seconds after power up, the LCD display on the Demo Board should display this brief greeting:
H E L L 0
The “HELLO” message should be followed by the display of accumulated energy alternating with the text “Wh”.
3.
0.
0
0
1
W
h
If the PB switch on the Demo Board is pressed and held down), the display will cycle through a series of
parameters, as shown in Table 1-4.
Step
Displayed
Text
Description
Step
Displayed
Text
Description
1
DELTA C
Deviation from nominal
temperature [°C]
10
DATE
Date from RTC [yyyy.mm.dd]
2
HZ
Line frequency [Hz]
11
PF
Power factor, calculated from current
Wh/VAh
3
Wh
Accumulated real energy
[Wh]
12
4
Wh
Exported real energy [Wh]
13
EDGES
5
VARh
Accumulated reactive energy
[VARh]
14
PULSES
Accumulated pulses
6
VARh
Exported reactive energy
[VARh]
15
A
Current
7
VAh
Accumulated apparent
energy [VARh]
16
V
Voltage
8
HOURS
Hours of operation since last
reset [1/100 h]
17
VBAT
Battery voltage
9
TIME
Real time from RTC
[hh.mm.ss]
--
--
--
Table 1-4: Selectable Display Parameters
Once, the Debug Board is plugged into J2 of the Demo Board, LED DIO1 on the Debug Board will flash with a
frequency of 1Hz, indicating CE activity. The LED DIO0 will flash with a frequency of 5Hz, indicating MPU
activity.
Содержание 71M6534H
Страница 2: ...71M6534H Demo Board User s Manual Page 2 of 86 2005 2007 TERIDIAN Semiconductor Corporation V2 0...
Страница 8: ...71M6534H Demo Board User s Manual Page 8 of 86 2005 2007 TERIDIAN Semiconductor Corporation V2 0...
Страница 40: ...71M6534H Demo Board User s Manual Page 40 of 86 2005 2007 TERIDIAN Semiconductor Corporation V2 0...