![Terex RMX HI-RANGER Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/terex/rmx-hi-ranger/rmx-hi-ranger_operators-manual_1088823039.webp)
RMX SERIES
1-5
R M X S e r i e s
T e r e x S o u t h D a k o t a
4 8 3 0 1 8 - 3 / 1 5
OPERA
T
ION GUIDELINES
CONTROLS BELOW ROTATION OPERATION
1.
Selector
Move handle up to activate “UNIT” system.
The Selector will function as an emergency stop by
taking oil flow away from the active control
.
Move handle down to operate outrigger system “O/R’S”.
2.
Outrigger
Controls
Move handle “UP” to raise outrigger.
Move handle “DOWN” to lower outrigger.
3.
Hydraulic Tools
(Optional)
Return handle to center position to turn off.
NOTE: Turn tool “OFF” before operating other
functions.
Move handle to energize tool quick couplers in direction
required. “ON” direction energizes male coupler.
4.
Engine Stop/Start
(Optional)
Push and hold to start engine. Release when engine starts.
Push and release to stop engine.
Can also be used to stop the Aerial Device in an
emergency.
5.
Two-Speed
Throttle
(Optional)
*Auxiliary Let
Down Power
(Optional)
With engine running, the throttle is activated.
Push and release to increase engine RPM.
Push and release to return to engine idle.
With engine “OFF”, the auxiliary let down power is activated.
Push and hold to turn on auxiliary let down power.
Release to shut off auxiliary let down power.
NOTE: *Can be included with two-speed throttle circuit. When vehicle engine is disabled,
the auxiliary let down power can be activated by the two-speed throttle switch.
NOTE: *Do not operate longer than 30 seconds. Continuous operation will drain battery
and/or overheat pump motor.
O/R’S
UNIT
SELECTOR
DOWN
UP
O/R
458712
TOOLS
RELEASE
ON
ENGINE
PUSH/RELEASE
STOP/START
437033
THROTTLE
PUSH/RELEASE
TWO SPEED
431560B
DC POWER
PUSH/HOLD
457452