First Edition • Third Printing
Operator's Manual
Inspections
Part No. 1290847GT
GS
™
-1330m 27
At the Platform Controls
Test Emergency Stop
19
Push in the platform red Emergency Stop
button to the off position.
Result: No functions should operate.
Test the Horn
20
Pull out the red Emergency Stop button to the
on position.
21
Press the horn button.
Result: The horn should sound.
Test the Function Enable Switch and the
Up/Down Functions
22
Do not hold the function enable switch on the
control handle.
23
Slowly move the control handle in the direction
indicated by the blue arrow, then in the
direction indicated by the yellow arrow.
Result: No functions should operate.
24
Press the lift function button.
25
Wait seven seconds for the lift function to time
out.
26
Slowly move the control handle in the direction
indicated by the blue arrow, then in the
direction indicated by the yellow arrow.
Result: The lift function should not operate.
27
Press the lift function button.
28
Press and hold the function enable switch on
the control handle. Slowly move the control
handle in the direction indicated by the blue
arrow.
Machines equipped with foot switch: Press and
hold the foot switch and press and hold the
function enable switch on the control handle at the
same time.
Result: The platform should raise. The pothole
guards should deploy.
29
Release the control handle.
Result: The platform should stop raising.