TECH TIP 02 | RELEASED 02.07.2022 | VERSION 1.0
STEP 4
Raise boom to full elevation or attach to a solid object with the load line. The object must be heavier
that what is indicated on the load chart.
Set throttle to maximum setting and engage lift up control. Verify on the gauge that the pressure is
set to what is shown on the unit placard.
If pressure is not at desired level, locate return manifold in pedestal. (Manifold shown below)
Adjust CW to increase setting or CCW to decrease setting. Adjust to specification listed on the unit
placard.
Return manifold with the current style system
relief cartridge.