Section 3 • Scheduled Maintenance Procedures
3 - 28
AL8000HT Light Tower
Part No. 116478
REV A
September 2008
CHECKLIST
E
PROCEDURES
9 Remove the suction strainer and clean it using a
mild solvent.
10 Rinse out the inside of the reservoir using a mild
solvent.
11 Install the suction strainer.
12 Install the hydraulic reservoir onto the power
unit.
13 Install the hydraulic reservoir retaining fasteners
and securely tighten. Do not overtighten.
14 Install the hydraulic power unit onto the
machine.
15 Fill the reservoir with hydraulic oil to within a
1/2" from the top with the cylinders collapsed.
16 Clean up any oil that may have spilled. Properly
discard the used oil.
17 Operate all machine functions through a full
cycle and check for leaks.
18 Operate all machine functions through 5-10 full
cycles to fully remove air from the system.
19 Make sure unit is in a clear area during steps 17
and 18 as air in the cylinders can cause sudden
movements of the tower.
E-2
Perform Engine Maintenance -
Kubota Models
Note: Engine specifications require that this
procedure be performed every 3000 hours.
Required maintenance procedures and additional
engine information is available in the
Kubota D-1105 and V-1505 Operator's Manual
(Kubota part number 16683-89169).
Kubota D-1105 and V-1505 Operator's Manual
Terex part number
893020
Содержание AL8000HT
Страница 1: ...Service Manual First Edition Rev A Part No 116478 September 2008 AL8000HT TM...
Страница 3: ...September2008 PartNo 116478 AL8000HTLightTower Serial Number Legend iii How to Read Your Serial Number...
Страница 97: ...Section 6 Schematics September2008 PartNo 116478 AL8000HTLightTower 6 15 REV A Hydraulic Schematic...
Страница 99: ......