11. The Ring Blow will be continuously at within the operation range shown on the wind flow rate to
static pressure curve (shown in the catalog). This operation range is so wide that the machine can
be operated at nearly closed pressure but, if you operate it at high pressure, especially take care
not to exceed the operation range. If you must operate it at closed condition, arrange a bypass
hole on the way, so that a more wind than required range flows through the blower even if the
suction port is closes (Figure 4).
Delivery Suction
Item
Model
sec
①
Q
②
sec
①
Q
②
VFC088A,088P Cont.
0
Cont.
0
VFC108A,108P 600
0.05 /
0.1
600
0.05 /
12. For using air intermittently, the switching by means of a valve is recommended rather than the
switching on and off of the motor (Figure 5). The standard for start and stop frequency of Ring
Blow shall be not higher than the values in table below.
①
Shut-off allowable time(sec)starting at a normal temperature.
②
Minimum required air flow at 50/60Hz
Q=
㎥
/min
(
Figure 5
)
For using with the suction side closed
Bypass hole
Valve
Valve
Release
Switch suction and blow using the valve.
(Suction)
(Blow)
Product
(
Load
)
Suction
Blow
(
Figure 4
)
Valve
For using with the discharge side closed
Bypass hole
Valve
0.1
VFC208A,208P
240
0.1 / 0.1
240
0.1 / 0.1
VFC308A,308P
120
0.3 / 0.4
120
0.3 / 0.4
VFC408A,408P
120
0 / 0.1
120
0 / 0.1
VFC508A,508P
60
0.2 / 1.3
60
0.2 / 1.2
VFC608A
60
0.8 / 1.6
60
0.8 / 1.6
VFC708A
30
1.8 / 2.5
30
1.5 / 2.0
VFC808A
30
2.5 / 4.0
30
2.0 / 3.0
VFC908A
30
4.0 / 5.5
30
3.0 / 4.0
10