background image

                                                                     TCG120-4_R1.3 

 May 2022  

                        Page 42 

       <Latitude>43.835283</Latitude> 
       <Longitude>25.965967</Longitude> 

                      </NetworkInfo> 
                </Monitor> 

 

 

Where: 

<value>--- </value> and <unit>--- </unit> means no 1-Wire sensor on this position; 

 <alarm>1</alarm> means there is a trigger condition. 

 
 
 
 
 

 

 

Содержание TCG120-4

Страница 1: ......

Страница 2: ...B SMS and HTTP API 2 digital dry contact inputs 2 analog inputs with 0 to 60VDC range 2 relays with NO and NC contacts 1 Wire support for all Teracom sensors MQTT 3 1 1 support SMS alarm alerts for up...

Страница 3: ...ccording to IEC 62368 1 10 to 28 VDC Current consumption 0 24A 12VDC Cellular interface Standards LTE FDD EDGE and GPRS TCG120 4E hv2 bands 4G LTE B1 B3 B5 B7 B8 B20 2G B3 B8 SIM card size Standard An...

Страница 4: ...tention Before installing the SIM card in the card slot please ensure that the PIN code is disabled 5 1 Mounting TCG120 4 should be mounted in a clean and dry location on a non flammable surface Venti...

Страница 5: ...gned to be supplied by adapter SYS1308 2412 W2E or similar intended for use in the conditions of overvoltage category II The power supply equipment shall be resistant to short circuits and overload in...

Страница 6: ...operation over mentioned wiring length We recommend reading Maxim s 1 Wire tips at https www maximintegrated com en design technical documents tutorials 1 148 html We guarantee proper operation only...

Страница 7: ...onitoring DC voltage up to 60VDC They can be connected directly to batteries solar panels power supplies etc The Multiplier Offset and Dimension for every analog input gives a possibility to monitor s...

Страница 8: ...when the corresponding relay is activated the NO contact is connected to COM SIG red indicates the status of the device together with STA STA yellow indicates the status of the device together with S...

Страница 9: ...nal strength is between 81 and 100 Error message in case of error after initialization SIG will stay solid OFF STA will flash showing the type of error STA flashes ones for 1s master phone number is n...

Страница 10: ...he TCG120 4 product page at www teracomsystems com After successful driver installation the device will be recognized as Mass storage the following window appears on the screen The only file stored on...

Страница 11: ...page For every sensor there is a description value and ID information The description length is up to 15 characters The descriptions can be changed on the Setup Conditions page Teracom temperature se...

Страница 12: ...ither remotely or locally from the status of a monitored parameter For locally activated relays a text describing the controlling parameter is displayed rather than buttons Pulse duration and paramete...

Страница 13: ...or by the button Scan All found sensors are shown in ascending order refer to their unique ID number It is possible to lock a 1 Wire sensor in a specific position To do this all sensors should be adde...

Страница 14: ...SON data SMS and e mail alerts For every analog input fields Unit Multiplier and Offset are available to convert the raw voltage current into meaningful engineering units The scaled value is calculate...

Страница 15: ...is 3600 seconds All relays can be activated either remotely by SMS HTTP API or locally from the status of a monitored parameter This setting is made from the Activated from drop down menu the possibl...

Страница 16: ...Min and Max indicate the border of the working range for the monitored parameter The Max trigger condition occurs when the value exceeds the trigger set point The Min trigger condition occurs when the...

Страница 17: ...eters are set for Sensor1 Min 19 Max 100 and Hys 0 5 When the module is switched on Relay1 is immediately activated because the monitored temperature is out of range This switches the heater on The te...

Страница 18: ...all sensors and for all analog inputs there is a Notification delay parameter It is very useful as a filter for short alarm conditions 7 2 4 2 Digital inputs For every digital input the alarm state s...

Страница 19: ...n be used for additional filtering On the picture above low to high and high to low delays are set to 0 1 seconds 7 2 5 System The page for some general settings 7 2 5 1 System status There is informa...

Страница 20: ...ly losing the connection with the device The automatic restart will be done once per day By default the automatic restart is disabled 7 2 5 4 General setup The section is for some general settings The...

Страница 21: ...k synchronization is made on the set Period If the attempt was not successful the next synchronization will be on If not found time Pressing the Save and synchronize button initiates time synchronizat...

Страница 22: ...entication details For most SMTP servers sender e mail and username are the same There is a button for server settings test with a feedback In this test sender and recipient of the e mail is the same...

Страница 23: ...in and 48 hours This parameter can be changed remotely by a command The Period determines at what time the control software receives up to date information from TCG120 4 and can therefore make changes...

Страница 24: ...TCG120 4_R1 3 May 2022 Page 24 7 4 MQTT Device supports MQTT 3 1 1 This page is for the MQTT settings 7 4 1 MQTT General 7 4 2 MQTT Sensors topic 7 4 3 MQTT analog inputs topic...

Страница 25: ...orks indoors It is especially suitable for tracking parcels refrigerated display cases refrigerators machines and equipment operating where there is no GPS signal TCG120 4 supports the following opera...

Страница 26: ...different rights master user Below is a list of the supported SMS commands Note that the underscore character must be replaced by one space character Set new master number Rights Master Syntax set ma...

Страница 27: ...play sms users Example Command display sms users Answer m 359885885885 u1 359885887766 u2 359885999888 u3 u4 Set email users this message is used to add delete email users Rights Master Superusers Syn...

Страница 28: ...SED Command status s22 Answer s22 Office 34 5 RH Set a relay this message is used to switch on off the selected relay output Rights Master Superusers Users Syntax set relay state option Where relay is...

Страница 29: ...RL s for XML JSON HTTP Post Rights Master Superusers Users Syntax status purl or status purl2 Example Command status purl Answer purl www teracomsystems com 8801 posttest php post on period 00 01 00 C...

Страница 30: ...rusers Syntax set mqtt off Example Command set mqtt off Answer mqtt off mdata json period 00 05 00 MQTT period sets MQTT publish period Rights Master Superusers Syntax set mper time Where time is betw...

Страница 31: ...23 Answer ts time google com 123 tz 02 00 Set a time zone Rights Master Superusers Syntax set tz hh mm Example Command set tz 03 00 Answer ts time google com 123 tz 03 00 Restart restarts the device R...

Страница 32: ...Answer Response timeout Answer Socket error Set Mobile network connection reset Rights Master Superusers Syntax set mncr status hh mm ss Where status on or off Example enable mobile network connectio...

Страница 33: ...be sent also on an alarm condition as an analogy of the SNMP trap On every HTTP Post the server returns a response in accordance with the HTTP protocol Only if Process Answer is enabled TCG120 4 will...

Страница 34: ...TP Post request 3 with updated XML JSON data which confirms the execution of set r1 on command The server returns a new HTTP response 4 which includes set FIN in the message body This indicates that t...

Страница 35: ...se echo The PHP script is working Copy the post php file on a WEB server with PHP support The server should have visibility from the Internet The UniServer and XAMP are the most popular WEB servers fo...

Страница 36: ...nput 1 snpt 30 0 Set Min of sensor to 30 0 p is 1 2 3 or 4 for the respective sensor t is 1 or 2 for the respective parameter of sensor sn12 30 0 will set Min for sensor 1 parameter 2 sxpt 40 0 Set Ma...

Страница 37: ...publish period to 600 seconds save Save all previous changes except relays one in the FLASH memory As every save reflects the FLASH cycles endurance this command should be used very carefully pper 12...

Страница 38: ...up to 2000 meters When the module is a part of a system the other elements of the system shall comply with the EMC requirements and shall be intended for use in the same ambient conditions 13 Safety T...

Страница 39: ...c cleaning device dust remover or any kind of abrasive materials to clean the device 15 Package content The box contains TCG120 4 Multi band antenna 698 to 960 and 1710 to 2690MHz Quick start guide Ap...

Страница 40: ...tem2 value value unit unit alarm 0 alarm min min max max hys hys item2 S3 S4 description S4 description id 0000000000000000 id type 1Wire type item1 value value unit unit alarm 0 alarm min min max max...

Страница 41: ...valuebin alarmState CLOSED alarmState alarm 0 alarm DI2 DI R R1 description Relay 1 description value OFF value valuebin 0 valuebin pulseWidth 0 1 pulseWidth control 0 control R1 R2 description Relay...

Страница 42: ...ay 2022 Page 42 Latitude 43 835283 Latitude Longitude 25 965967 Longitude NetworkInfo Monitor Where value value and unit unit means no 1 Wire sensor on this position alarm 1 alarm means there is a tri...

Страница 43: ...o teracomsystems com SysName TCG120 4 SysLocation Location S S1 description S1 TST230 id 010140C6E8FFCE65 type 1W item1 value 29 0 unit C alarm 0 min 40 0 max 50 0 hys 0 5 item2 value 51 1 unit RH ala...

Страница 44: ...alarm 0 min max hys AI AI1 description Analog Input 1 value 0 000 unit V multiplier 1 000 offset 0 0000 alarm 0 min 0 000 max 2 000 hys 0 010 AI2 description Analog Input 2 value 0 000 unit V multipli...

Страница 45: ...lseWidth 0 1 control 0 R2 description Relay 2 value OFF valuebin 0 pulseWidth 0 2 control 0 HTTPPush Key PushPeriod 300 MQTT Period 300 signalpercent 67 hwerr Alarmed 0 Scannig Scan Time Date 11 08 20...

Страница 46: ...TCG120 4_R1 3 May 2022 Page 46 Appendix C Fig 1 Fig 2...