Trigonometric correction / length unit
20
V-11/2018
6
Trigonometric correction / length unit
Notice
In the factory setting, the length unit is set to “m” (metres). It can
be changed to “ft” (feet).
Notice
In the factory setting, the trigonometric correction is activated.
If the elevation unit cannot stabilise freely (e.g. due to cable tension), the
trigonometric correction can correct the deviation.
If the trigonometric correction is activated, a deviation from perpendicular is
corrected. The corrected value is shown on the display. If it is deactivated, the
actual reading of the crooked measurement, which could be incorrect, will be
displayed.
► Remove the two caps (1) on the display unit with a small screwdriver.
► Unscrew both screws (2).
► Remove the cover.
► Set DIP switches (3) and (4).
► Set length unit to metres or feet – DIP switch 1, left (3):
-
Metres: Set DIP switch 1 to “ON”.
-
Feet: Set DIP switch 1 to “OFF”.
► Activate/deactivate trigonometric correction – DIP switch 2, right (4):