Tense TPM-05 Скачать руководство пользователя страница 7

Figure-18

Figure-19

Figure-20

Figure-21

Figure-22

L1

L2

L3

I

A

A

A

Out1

Din1

Out2

L1

L2

L3

I

A

A

A

Out1

Din1

Out2

L1

L2

L3

I

A

A

A

Out1

Din1

Out2

L1

L2

L3

I

A

A

A

Out1

Din1

Out2

L1

L2

L3

I

A

A

A

Out1

Din1

Out2

    

Figure-18:

 

It shows current values of each phase. When you press the right key, figure-19 comes to 

the screen.

    

Figure-19:

 

It shows the minimum (Min) current values of each phase. When you press the right key, 

figure-20 comes to the screen.

    

Figure-20:

 

It shows the maximum (Max) current values of each phase. When you press the right key, 

Figure-21 comes to the screen.

    

Figure-21:

 

It shows the average (Ave) current values of each phase. When you press the right key,

Figure-22 comes to the screen.

    

Figure-22:

 

It shows current demand (Dmd) values for each fuse. When you press the right key,

Figure-23 comes to the screen.

    

    Figure-23:

 

It shows the time and date of demands which 

belongs to each phase. When you press the right key ,values 

which belongs to the L2 and L3 comes to the screen 

subsequently. When you press the right key,

 

Figure-24 comes 

to the screen.

    

Figure-24:

 

It shows the time and date which current limit

(

>

Ctr x 0.80) of each phase is exceeded. When you press the 

right key ,values which belongs to the L2 and L3 comes to the screen 
subsequently. When you press the right key,

 

Figure-25 comes to the screen.

Figure-23

L1

I

Out1

Din1

Out2

Figure-24

L1

I

Out1

Din1

Out2

-6-

    

Figure-25:

 

It shows the active power (P) values for each zone. When you press the right button, the screen 

will show figure-26.

    

Figure-26:

 

It shows the maximum active power (P) values for each zone. When you press the right key 

figure-27 comes to the screen.

    

Figure-27:

 

It shows average(Ave)  active power(P) value of each phase. When you press the right key,

 

Figure-28 comes to the screen.

    

Figure-28:

 

It  shows the active power (P) demand (Dmd) values for each zone. When you press the right 

key,

 

Figure-29 comes to the screen.

    

Figure-29:

 

It shows the time and date of  active power(P) demands of each phase. When you press the 

right key ,values which belongs to the L2 and L3 comes to the screen subsequently. When you press the 

right key,Figure-30 comes to the screen.

Figure-25

Figure-26

Figure-27

Figure-28

Figure-29

L1

L2

L3

P

kW

kW

kW

Out1

Din1

Out2

P

L1

L2

L3

kW

kW

kW

Out1

Din1

Out2

P

L1

Out1

Din1

Out2

P

L1

L2

L3

kW

kW

kW

Out1

Din1

Out2

P

L1

L2

L3

kW

kW

kW

Out1

Din1

Out2

Содержание TPM-05

Страница 1: ...he phase to phase and Phase neutral voltages V It shows the values of each phase and total current I1 I2 I3 I It shows total import and export active kWh energy It shows total inductive and capacitive...

Страница 2: ...Out1 Out1 Out2 Out2 Out2 RS485 RS485 RS485 A A A B B B GND GND GND N N N L1 L1 L1 L2 L2 L2 L3 L3 L3 Max 5A AC Max 5A AC Max 5A AC I 1 I 1 I 1 I 2 I 2 I 2 I 3 I 3 I 3 I3 I3 I3 k3 k3 k3 I2 I2 I2 k2 k2 k...

Страница 3: ...d shielded or twisted cord cable at the non network connected input and output lines These cables should not be passed near the high power lines and the device Assembling and electrical connections mu...

Страница 4: ...es are inductive 3 Indicates displayed values V voltage I current F frequency S apparent power P active power PF power factor THD I total current harmonics THD V total voltage harmonics Q reactive pow...

Страница 5: ...sed while not in the menu the screen always shows figure 4 This button enables to fast progress between the values that are measured out of menu This button allows to progress by displaying the measur...

Страница 6: ...L23 L31 V V V V Out1 Din1 Out2 L12 V Out1 Din1 Out2 Figure 9 Illustrates the date and time in which phase neutral voltage goes above 110 Vtr x 230 x 1 1 of the nominal voltage values swl When you pre...

Страница 7: ...shows the time and date which current limit Ctr x 0 80 of each phase is exceeded When you press the right key values which belongs to the L2 and L3 comes to the screen subsequently When you press the...

Страница 8: ...t1 Din1 Out2 Q L1 L2 L3 kVAr kVAr kVAr Out1 Din1 Out2 Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 L1 L2 L3 S S S S S Var Var Var Out1 Din1 Out2 L1 L2 L3 Var Var Var Out1 Din1 Out2 L1 L2 L3 Var V...

Страница 9: ...creen respectively When the right button is pressed Figure 49 comes to the screen Figure 49 It shows the import active inductive reactive and capacitive reactive energy values which belongs to total o...

Страница 10: ...A A A Out1 Din1 Out2 Figure 25 L1 L2 L3 P kW kW kW Out1 Din1 Out2 Figure 4 L1 L2 L3 V V V V Out1 Din1 Out2 Figure 11 L12 L23 L31 V V V V Out1 Din1 Out2 Figure 30 L1 L2 L3 Q kVAr kVAr kVAr Out1 Din1 Ou...

Страница 11: ...on screen figure 58 password inquiry is displayed on the screen If a password has been created enter the password and press the set key If password is not created when you press set key while value i...

Страница 12: ...ure 71 To change the RS 485 remote communication settings press the set button while figure 61 is on the screen Figure 71 comes to the screen Two parameters can be set here Baudrate br communication s...

Страница 13: ...recorded when you press the Set key and figure 66 comes to the screen Pressing the right key you can pass through the parameters in the menu or pressing Esc key you can quit the menu Time display is o...

Страница 14: ...nput should be minimum at one second 1Hz Example When the voltage rises above 250V switch on relay 1 Parameters PAr ULn function fun hl and value VAL 250V should be set After the relay 1is set like th...

Страница 15: ...emand Values Hour Baudrate I Un Current Imbalance Low Voltage Dip Swl Cut Lmt I Lmt Thd V Lmt Thd I Lmt PF dI n High voltage No Voltage Current Limit Thd V Limit Thd I Limit Power Factor Limit Data In...

Страница 16: ...Communication Display 15 14 Technical Specifications 16 Contact Informations Merkez Mah Akalar Sok No 39A GAZ OSMANPA A STANBUL T RK YE Tel 90212 578 04 38 48 Fax 90212 578 04 36 Web Mail info tense c...