Tense TPM-05 Скачать руководство пользователя страница 15

-14-

12 - 

Menu Values Table:

Parameter

Minimum 

Value

Factory

Value

Unit

Maximum 

Value

Parameter

Number

5000

0.99

No

-
-
-

247

No

115200

3P3L

2100

Low

-

999.9

50

No

50

9999

50
50

1

0.50

Yes

-
-
-
1

Yes

1200

3P4L
2000

High

-

0.1

1

Yes

OFF, Uln, Iln, Ilt, thdU,  

thdI, PF, U Un, I Un, dI n 

1

0

1
1

1

0.50

No

1
8

none

1

No

9600

3P4L

-

High

vtr x 10

vtr x 10

vtr x 500

(ctrx10)/100

-

1.0

1

No

OFF

1

0

(ctrx3x10)/100 (ctrx3x10)/100

1
1

-

%

-

-
-
-
-
-

bps

-
-

-

Volt

Amper

-

-

%

-

-

%
%
%
%
%
%
%
%
Hz.

-

Amper

%
%

Ctr

dE

-
-
-

Id

En

Con Type

Date Set

Fun

UAL

Time Set

Vtr

LO

Par

br

PASS

Current Transformer Ratio

PF (Power Factor)

Deleting Demand Values

Hour

Baudrate

I Un (Current Imbalance)
Low Voltage

Dip

Swl
Cut

Lmt I

Lmt Thd-V

Lmt Thd-I

Lmt PF
dI n

High voltage
No Voltage
Current Limit
Thd-V Limit

Thd-I Limit

Power Factor Limit
Data 

I

nput 

F

requency

Password

Deleting Total Energy

Stop bits
Data bits
Parity
ModBus ID

Connection Type

Date

Function
Uln (voltage)
Iln (Current)
Ilt (Total Current)
thdU (Total Voltage Har.)
thdl (Total Current Har.)

Voltage Transformer Ratio

U Un (

V

oltage imbalance)

Deleting Event Records

Parametre

(ctrx10)/100

(ctrx500)/100

(ctrx3x500)/100

 13- Dimensions:

97,5 mm

96,5 mm

56,75 mm

65 mm

96,5 mm

89,5 mm

12mm

5,08 mm

<

Vtr x 230 x 0,90  ve 

<

Vtr x 400 x 0,90

<

Vtr x 230 x 0,40  ve 

<

Vtr x 400 x 0,40

>

Vtr x 230 x 1,10  ve 

>

Vtr x 400 x 1,10

>

1.20

>

1.20

<

0.80

>

1Hz.

>

Ctr x 0.80

Содержание TPM-05

Страница 1: ...he phase to phase and Phase neutral voltages V It shows the values of each phase and total current I1 I2 I3 I It shows total import and export active kWh energy It shows total inductive and capacitive...

Страница 2: ...Out1 Out1 Out2 Out2 Out2 RS485 RS485 RS485 A A A B B B GND GND GND N N N L1 L1 L1 L2 L2 L2 L3 L3 L3 Max 5A AC Max 5A AC Max 5A AC I 1 I 1 I 1 I 2 I 2 I 2 I 3 I 3 I 3 I3 I3 I3 k3 k3 k3 I2 I2 I2 k2 k2 k...

Страница 3: ...d shielded or twisted cord cable at the non network connected input and output lines These cables should not be passed near the high power lines and the device Assembling and electrical connections mu...

Страница 4: ...es are inductive 3 Indicates displayed values V voltage I current F frequency S apparent power P active power PF power factor THD I total current harmonics THD V total voltage harmonics Q reactive pow...

Страница 5: ...sed while not in the menu the screen always shows figure 4 This button enables to fast progress between the values that are measured out of menu This button allows to progress by displaying the measur...

Страница 6: ...L23 L31 V V V V Out1 Din1 Out2 L12 V Out1 Din1 Out2 Figure 9 Illustrates the date and time in which phase neutral voltage goes above 110 Vtr x 230 x 1 1 of the nominal voltage values swl When you pre...

Страница 7: ...shows the time and date which current limit Ctr x 0 80 of each phase is exceeded When you press the right key values which belongs to the L2 and L3 comes to the screen subsequently When you press the...

Страница 8: ...t1 Din1 Out2 Q L1 L2 L3 kVAr kVAr kVAr Out1 Din1 Out2 Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 L1 L2 L3 S S S S S Var Var Var Out1 Din1 Out2 L1 L2 L3 Var Var Var Out1 Din1 Out2 L1 L2 L3 Var V...

Страница 9: ...creen respectively When the right button is pressed Figure 49 comes to the screen Figure 49 It shows the import active inductive reactive and capacitive reactive energy values which belongs to total o...

Страница 10: ...A A A Out1 Din1 Out2 Figure 25 L1 L2 L3 P kW kW kW Out1 Din1 Out2 Figure 4 L1 L2 L3 V V V V Out1 Din1 Out2 Figure 11 L12 L23 L31 V V V V Out1 Din1 Out2 Figure 30 L1 L2 L3 Q kVAr kVAr kVAr Out1 Din1 Ou...

Страница 11: ...on screen figure 58 password inquiry is displayed on the screen If a password has been created enter the password and press the set key If password is not created when you press set key while value i...

Страница 12: ...ure 71 To change the RS 485 remote communication settings press the set button while figure 61 is on the screen Figure 71 comes to the screen Two parameters can be set here Baudrate br communication s...

Страница 13: ...recorded when you press the Set key and figure 66 comes to the screen Pressing the right key you can pass through the parameters in the menu or pressing Esc key you can quit the menu Time display is o...

Страница 14: ...nput should be minimum at one second 1Hz Example When the voltage rises above 250V switch on relay 1 Parameters PAr ULn function fun hl and value VAL 250V should be set After the relay 1is set like th...

Страница 15: ...emand Values Hour Baudrate I Un Current Imbalance Low Voltage Dip Swl Cut Lmt I Lmt Thd V Lmt Thd I Lmt PF dI n High voltage No Voltage Current Limit Thd V Limit Thd I Limit Power Factor Limit Data In...

Страница 16: ...Communication Display 15 14 Technical Specifications 16 Contact Informations Merkez Mah Akalar Sok No 39A GAZ OSMANPA A STANBUL T RK YE Tel 90212 578 04 38 48 Fax 90212 578 04 36 Web Mail info tense c...

Отзывы: