Fault
1. The drive does not
start, the LCD display
does not light up.
2. No limit
positions.
Error system
Set the limit
positions again.
a) No power supply.
b) The power cord
is damaged.
a) Check whether the motor
socket is energized.
b) Check that the fuse is not damaged.
c) Check that the transformer low voltage
cable is connected to the power board.
d) Check that the wires are
connected to the board.
e) Check if the transformer’s low voltage side
is 26 V AC. If there is voltage - replace the
PCB, while if there is no voltage - replace the
transformer.