OPERATION
Tennant T5e (09--08)
15
ec- H2O
SYSTEM
INDICATOR LIGHT CODE CONDITION
Solid green
Normal operation
Blinking red
Flush
ec--H2O
module
Solid red
Contact Service Center
BATTERY METER
The battery meter displays the charge level of the
batteries (Figure 28). When the batteries are fully
charged, all indicator lights will glow. As the batteries
discharge, the indicator lights will begin to go out from
right to left
When the discharge level reaches the first red light
(Figure 28), stop scrubbing and recharge the batteries.
If you continue to operate the machine beyond the first
red light, the scrubbing function will automatically shut
off when the last red light begins to blink. This protects
the batteries from total discharge. Drive the machine to
the charging area and recharge the batteries
immediately.
NOTE:
The battery meter will also display machine
fault codes. If a fault is detected the LED bars will flash
specific fault codes (See BATTERY METER LED
FAULT CODES).
Stop scrubbing and recharge batteries
FIG. 28
HOUR METER
The hour meter records the number of total hours the
brush motors have been powered on. Use the hour
meter to determine when to perform recommended
maintenance procedures and to record service history
(Figure 30). See MACHINE MAINTENANCE.
FIG. 29
CIRCUIT BREAKERS / FUSES
The machine is equipped with four resettable circuit
breakers and four fuses to protect the machine from
damage. If a breaker should trip, determine the cause,
allow the motor to cool then manually reset the circuit
breaker button. The circuit breaker panel is located
near the battery compartment (Figure 30). The fuses
are located inside the circuit breaker box. When
replacing a fuse never substitute a higher Amp rated
fuse than specified.
CIRCUIT BREAKERS:
10 A -- Main (A)
25 A -- Vacuum motor (B)
25 A -- Left brush motor (C)
25 A -- Right brush motor (D)
FUSES:
100 A -- Main
30 A -- Propel motor
7.5 A -- FaST system
7.5 A -- FaST system
7.5 A -- Off--aisle wand pump (located in control
console)
A
B
C
D