T5e
ec-H2O
Kit
INSTALLATION INSTRUCTIONS --
Continued
Page 2 of 9
KIT NO. 9006828
9006829 Rev. 00 (12--09)
Tennant Company
Customer Service: (800) 553--8033 or (763) 513--2850
4. Using Nut [p/n 09739], attach Relay [p/n 1012216]
to the mounting stud located inside the circuit
breaker box (Figure 6). Connect
ec--H2O
harness
wire to relay
(See Figure 4 for relay reference)
.
Relay
mounting
stud
Fig. 6
5. Connect
ec--H2O
harness connector to the open
connector located inside the circuit breaker box
(Figure 7).
ec--H2O
Harness
Connector
Fig. 7
6. Route the following
ec--H2O
harness wires to
control console as described in steps 7 and 8
(Figure 8).
To LED Light
To
ec--H2O
on/off Switch
Fig. 8
7. Remove the vacuum motor cover (Figure 9).
Vacuum
motor cover
Fig. 9
8. Remove the vacuum motor and route
ec--H2O
harness wires (Figure 8) through the recovery
tank harness hole and into the control console
(Figure 10). Replace vacuum motor and cover.
ec--H2O
Harness
Wires
To Control
Console
Fig. 10
9. Remove factory installed clamps and replace with
larger cable clamps [p/n 606697] to secure
ec--H2O
harness (Figure 11).
Clamps
[p/n 606697]
Fig. 11