S10 SERVICE INFORMATION
Electrical Troubleshooting
S10 331585 (6--07)
35
Key ON Power Distribution
Conditions: Key ON, Charger OFF
12 VDC
12 VDC
CB2
CB1
15 AMP
60 AMP
F1
TO SHAKER
MOTOR
M1B
M2B
MG2
M2A
4/YEL
6/BLU
H1
ONBOARD
CHARGER
SW1
KEY SWITCH
S1
THERMO--
SENTRY
MAIN
CONTACTOR
HOUR METER
1
MAIN CONTACTOR
+
--
SHAKER RELAY
52/BRN
62/BRN
5/GRN
72/BRN
BLK
MAIN DRIVE MOTOR
1/RED
1/RED
1/RED
1/RED
13/BLK
13/BLK
BLK
6/BLU
5/GRN
5/GRN
5/GRN
9/WHT
i
If battery voltage drops below 20.76 VDC (1.73
Volts per cell), the Battery Discharge Indicator
will open pins 3 & 4, shutting the machine OFF.
2
13/BLK
BATTERY
INDICATOR
DISCHARGE
3
4
U2
13/BLK
H1
+
--
9/WHT
9/WHT
25 AMP
Wiring Color Codes
Hour Meter is ON whenever Key Switch is
turned ON (unless charger is plugged in).