MAINTENANCE
800D MM308 (3–95)
64
HYDRAULICS
HYDRAULIC FLUID RESERVOIR
The reservoir is located behind the operator seat.
Mounted on top of the reservoir is a filler cap with
a built-in breather. Replace the cap every
800 hours of operation.
Check the hydraulic fluid level at operating
temperature every 100 hours of operation. Make
sure the hopper is down when checking hydraulic
fluid level. The sight gauge is marked with full, the
black line, and add, the red line, levels to indicate
the level of hydraulic fluid in the reservoir.
Lubricate the filler cap gasket with a film of
hydraulic fluid before putting the cap back on the
reservoir.
ATTENTION! Do not overfill the hydraulic fluid
reservoir or operate the machine with a low
level of hydraulic fluid in the reservoir.
Damage to the machine hydraulic system may
result.
Drain and refill the hydraulic fluid reservoir with
new hydraulic fluid every 800 hours of operation.
The hydraulic fluid filter is located in the engine
compartment.
Replace the filter element every 800 hours of
operation.
The reservoir has a built-in strainer outlet that
filters hydraulic fluid before it enters the system.
Replace the strainer every 800 hours of operation.
08452
08430
08453