OPERATION
810 Gas/LPG 330160 (3--07)
28
CIRCUIT BREAKERS
The circuit breakers are resetable electrical circuit
protection devices. Their design stops the flow of
current in the event of a circuit overload. Once a
circuit breaker is tripped, it must be reset
manually. Press the reset button after the breaker
has cooled down.
If the overload that caused the circuit breaker to
trip is still there, the circuit breaker will continue to
stop current flow until the problem is corrected.
All but two of the circuit breakers are located in
the operator compartment. There are two 30 Amp
circuit breakers located behind the circuit breaker
panel that can be accessed by raising the hopper.
The 30 Amp circuit breakers are self--resetting:
they will reset themselves, after cooling down,
after being tripped.
The chart lists the circuit breakers and the
electrical components they protect.
Circuit
Breaker
Rating
Circuit Protected
CB--1
15 A
Horn
CB--2
15 A
Filter shaker
CB--3
15 A
Controls
CB--4
15 A
Instrument panel
CB--5
15 A
Hazard light
CB--6
2.5 A
Brushes
CB--7
15 A
Left side brush option
CB--8
15 A
Cab accessories
CB--9
15 A
Accessories
CB--10
30 A
AC compressor/blower
CB--11
30 A
AC condenser/fans