ENGLISH
EN
SpeedScrub 2401/2601 (04–97)
9
SCRUB
STRIP
RED ZONE
PAD PRESSURE METER
CLEANING
RANGE
FIG. 17
CAUTION: To prevent possible floor
damage and brush circuit breakers from
tripping, do not operate machine with brush
pressure needle in the red zone.
11. To operate machine in reverse, simply pull
reverse switch backwards (one speed).
(Figure 18)
FIG. 18
12. To stop machine, release control grips.
WHILE OPERATING MACHINE
WARNING: Keep hands and feet clear of
revolving pad or brush.
1.
Observe amount of solution flow on floor.
Adjust solution control lever to desired flow.
To increase or decrease the maximum
solution flow, turn solution flow adjustment
knob clockwise to increase or
counterclockwise to decrease. Adjustment
knob is located at rear of machine.
(Figure 19)
FIG. 19
2.
Periodically check for foam buildup in
recovery tank
(look through clear lid). If
excessive foam buildup begins to develop,
pour a recommended foam control solution
into recovery tank.
CAUTION: Do not allow foam or water to
enter vacuum ball float screen, vacuum motor
damage will result. Foam will not activate ball
float. Vacuum motor damage due to foam or
water is not covered by warranty.
3.
Always operate at a slower speed when
scrubbing around walls or obstacles.
4.
Always reduce speed to maintain control
when turning machine.
5.
If squeegee leaves streaks, raise and wipe
blades with a cloth. Pre-sweep area to
prevent streaking.
6.
Overlap each pass by 2” (5cm).
7.
Change or turn over pads when dirty.
8.
Stay clear of floor obstructions, such as
electrical plates or grates, they will destroy
pads.
9.
During brief stops, you do not have to turn off
any switches, the brushes and solution flow
will automatically stop when control grips are
released.
10. Periodically check battery meter discharge
level. When needle drops to the red zone,